Connection
OMCTT5639E09
26
5.2 Input and ground (PE) cable connection
(1) Turn off power at the distribution box.
(2) Connect grounding conductor to supply grounding ter
-
minal.
(3) Connect input power conductors to (-) minus terminals
of the power box.
WARNING
The frame of this power source must be grounded to protect operat
-
ing technician from potentially deadly electrical shock.
WARNING
Never pull or apply undue force on primary cable once it has been
installed. Cable could disconnect from terminals and pose a threat
of potentially deadly electric shock.
WARNING
TURN OFF the power switch at the power distribution box before connecting
ground and input cables
CAUTION
The wiring and grounding work should be performed by educated and/or
skilled person.
Input power cable
Diameter
Length
Note
AWG 8
8.2 ft. (2.5 m)
4 conductors (including grounding conductor.)
Ground cable
Make sure to use one with diameter equal to or larger than that of the input power cable.
1
Input power cable
2
Power box
3
GND/PE
1
2
3