Section 700 Operation
Chapter 2.
teatures
Related Programming
l
(System):
Multiple DID (CPC-B Version 3.1 or higher)
l
(Extension): Inbound DID Dial Number (CPC-B Version 2.0 to 2.16)
l
FF4 (Ring): DID, Delayed, Night , Delayed Night, Night 2, and Delayed
Night 2 Ring Assignments
Hardware Requirements
l
Either the T-l Card or DID trunk card is required. Each DID trunk card
provides 8 ports.
l
The DID trunk card requires an external 48V power supply. See
Installation (Section
300) for instructions.
Considerations
l
The DID Trunk card supports
dial-pulse DID.
. The
card supports 4-digit, dial-pulse or
DID.
l
DID numbers must be between 0000 and 9999.
l
Beginning with CPC-B Version 3.1, a maximum of 500 DID/extension
settings is allowed.
DID Night Ringing Assignment
(CPC-B Version 5.0 or higher)
Description
For a description of this feature, see
Flexible Ring Assignments”
on page 18.
DBS-70-700
DBS Manual Issued
Page 2-17