Chapter 4
Settings — [PICTURE] menu
ENGLISH - 89
1) Press
as
to select [DYNAMIC CONTRAST NX].
2) Press
qw
or the <ENTER> button.
f
The
[DYNAMIC CONTRAST NX]
individual adjustment screen is displayed.
3) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the DYNAMIC CONTRAST NX function.
[1]
Adjusts the light source and compensates signals to a small extent.
[2]
Adjusts the light source and compensates signals to a moderate extent.
[3]
Adjusts the light source and compensates signals to a large extent.
[USER]
Set any desired correction.
Refer to “Performing desired correction” (
x
page 89) for details.
Note
f
[DYNAMIC CONTRAST NX] cannot be set when [DYNAMIC CONTRAST] is set to anything other than [OFF].
f
To use the contrast synchronization function and the shutter synchronization function, make the menu setting identical for each linked
projector either by setting [PICTURE] menu
→
[DYNAMIC CONTRAST NX] to anything other than [OFF] or by setting [PICTURE] menu
→
[DYNAMIC CONTRAST] to anything other than [OFF].
Set [DYNAMIC CONTRAST NX] to [OFF] and [DYNAMIC CONTRAST] to anything other than [OFF] when there are projectors without
[DYNAMIC CONTRAST NX] menu grouped into the linked projectors.
Performing desired correction
1) Press
as
to select [DYNAMIC CONTRAST NX].
2) Press
qw
or the <ENTER> button.
f
The
[DYNAMIC CONTRAST NX]
individual adjustment screen is displayed.
3) Press
qw
to select [USER].
4) Press the <ENTER> button.
f
The
[DYNAMIC CONTRAST NX]
screen is displayed.
5) Press
as
to select the item to set.
f
The items of the detailed settings will switch each time you press
qw
.
f
Press the <ENTER> button when [MULTI PROJECTOR SYNC] is selected.
Setting item
Details
[AUTO CONTRAST]
(Automatic light source
adjustment)
[OFF]
Does not adjust the light source.
[1] - [255]
The higher the value, the stronger the light adjustment of the light
source.
Can be set in increments of 1. (Factory setting: 215)
[BRIGHT SIGNAL LEVEL]
(Setting of the brightness
level of the signal to start the
light adjustment)
[6%] - [50%]
Adjusts the light source when the brightness level of the image
signal being input gets lower than the set value. The higher the
value, the larger the range to perform the light adjustment of the
light source.
Can be set in increments of 1 %. (Factory setting: 30 %)
[LIGHTS OUT TIMER]
(Time setting until the light
turns off)
[DISABLE]
Does not turn off the light source.
[0.0s] - [10.0s]
Turns off the light source when the brightness level of the image
signal being input goes under the value set in [LIGHTS OUT
SIGNAL LEVEL].
Select an item from [0.0s] - [4.0s], [5.0s], [7.0s], or [10.0s].
[0.0s] - [4.0s] can be selected in increments of 0.5.
[LIGHTS OUT SIGNAL
LEVEL]
(Setting of the brightness
level of the signal to turn off
the light)
[0%] - [5%]
Sets the level of the brightness of the image signal to turn off the
light source with [LIGHTS OUT TIMER].