266
Troubles
Causes
Measures
The sending command is
not accepted by the laser
marker. (NAK response)
DIP switch No. 2 on back of laser
marker is off.
To control the following commands with the serial
communication, turn ON DIP switch No. 2.
•
Laser Control (LSR)
•
Shutter Control (SHT)
•
Laser Check Radiation (SPT)
•
Test Marking (TST)
•
Guide LD Indication (GID)
•
Laser Power Measurement (PWM)
•
Power Check (PWR)
“Reception mode ON” is not set for
command reception permission (MKM
command)
The laser marker does not accept commands
except the following unless it is in the “reception
mode ON” status.
For command transmission, set “reception mode
ON” for “command reception permission (MKM
command)”.
• File Change (No. Specified) (FNO)
• File Change (Comment Specified) (FNN)
•
Shutter Control (SHT)
•
Command Reception Permission (MKM)
•
Laser Control (LSR)
•
Counter Reset (CTR)
•
Status Request (STS)
•
Marking Trigger (MRK)
•
Serial Data Input (SIN)
•
Serial Offset (SEO)
•
Error Code (ECR)
Alarm or error occurs.
All commands except the following are refused
while alarm or error is active.
When alarm occurred:
•
Status Request (STS)
•
Error Code (ECR)
When warning occurred:
•
Status Request (STS)
•
Error Code (ECR)
•
Shutter control (SHT) (Only for closing request,
and readout)
•
Command Reception Permission (MKM) (Only
for reception mode ON and reception mode
readout)
Two or more command data are
transmitted at the same time.
After sending the command, confirm the response
data from the laser marker. Do not send the next
command before receiving the response.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...