116
Serial Data
The serial data function is convenient for changing the marking character string at every marking by the communication
command. Set the “Serial Data No.” and “Figure”.
For communication command for marking character string using the serial data function, refer to Serial Communication
Guide.
Reference
•
Serial data marking function cannot be used in combination with rank marking, external offset by I/O, and equidistant
marking on the flying object.
1.
Press [FUNC. CHAR.] (FUNCTION
CHARACTER).
2.
Press [DATA].
Select the serial data No.
Select the display figure.
3.
Press [INPUT] and then, press [SET].
When setting the serial data function, the circle symbols
with the specified number of digits appear on the image
display. When it is set in the bar code or 2D code data,
the code symbol is generated with the specified digits of
“0” on the image display.
Setting item
Serial Data No.:
Setting Range
0 to 15
Number of Display Figure:
Set the max. number of the characters that will be input by the serial communication.
If the specified digit number and the character digits set by the communication command are different, the
communication command setting is valid for the character digits.
Setting Range
0 to 30
Display in the marking character field of the serial data function
%MM:Sn
: Serial data character
Item
Display
Description
MM
00 to 30
Represents the number of max. character digits to be input as serial data character.
n
Represents the serial data number.
0 to 9
Serial data No. 0 to Serial data No. 9
A to F
Serial data No. 10 to Serial data No. 15
1
2
3
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...