203
Mark “1234567890ABCDEF” with LP-S205/S505 (Marking field: 160 mm x 160 mm)
First, set the character string to be marked on the character setting screen.
Set the character string with its width of the character string per one line should be around 106 mm. (except the last layer
number)
1st line: 12345678 (character string width: 112 mm)
2nd line: 90ABCDEF (character string width: 112 mm)
Next, set the marking condition of each line on the marking condition setting screen. The setting should be:
“Condition No. 1, Layer No. 0” for the 1st line
“Condition No. 2, Layer No. 1” for the 2nd line
9 0 A B C D E F
1 2 3 4 5 6 7 8
Moving direction: LEFT
Moving direction: LEFT
Downstream
Downstream
Upstream
Upstream
Calculate the start position of “9”, which is the
head character of Layer No. 1 on the X coordinate
using the following formula:
Formula: -80 + (character string width on the 1st
line -160 mm x 2/3)
In this sample, the character string width on the
1st line is 112 mm, and therefore the calculation
will be:
Starting position of the head character on the X
coordinate = -80 + (112 - 160 x 2/3) ≈ -75
Make sure that the width of the character string
should match with or go over the projection line on
the marking image screen.
Character condition of “12345” on the 1st line
Character condition of “67890” on the 2nd line
Character condition No. 1
Character Height
Character Width
Character Interval
: 12
: 12
: 14
X Position
Y Position
Layer No.
: -80
: 0
: 0
Character condition No. 2
Character Height
Character Width
Character Interval
: 12
: 12
: 14
X Position
Y Position
Layer No.
: -75
: 0
: 1
Reference
•
Specify the character setting so that the last character in the character string should match with or go over the projection
line on the marking image screen. The projection line on the marking image screen indicates x 2/3 of marking field (starting
of the next marking field). (There may be the cases that the characters set outside of the guide line (the characters in the
upstream of moving direction) cannot be marked during low-speed operation.)
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...