230
System Offset
This screen specifies the offset of marking position and laser power to the all registered files.
The functions are applicable to adjust the difference of laser power or displacement between laser marker and works in
case multiple production lines are used.
Item
Description
3
Laser Power
:
Laser power offset. Offset the value of laser power set in each file.
Setting Range
50 to 200%
Reference
•
The laser power offset refers to the function to correct not the maximum laser power [W] value, but the laser power
setting value.
• “100” is specified if the value of “laser power (system offset)” × “laser power (laser setting)” is 100 or more.
4
Rotation Offset
: Rotates the object to the rotation direction around the
original point.
Setting Range -180.00 to +180.00 degree
+Y
-Z
-Y
+X
-X
+Z
Rotation (+)
Rotation (-)
5
X/Y Offset
: Shifts the marking position to the X/Y direction.
Setting Range
-30.000 to +30.000 mm
(LP-M500/LP-S500)*
Z Offset
(LP-M/LP-Z series
only)
: Shifts the marking position to the Z direction.
Setting Range
-22.000 to +22.000 mm (LP-M500)*
-25.000 to +25.000 mm (LP-Z130)*
Notice
•
The work distance adjusted with the Z-offset setting should conform with the actual distance from the head base
to the marking surface for the proper marking performance.
6
X/Y Scale
:
Sets the offset scale of marking field (X and Y). Area is corrected by inputting
magnification.
Setting Range
70.000 to 130.000%
*
For the setting range of the other model, refer to “Input Setting Value by Series” (P.296).
Reference
•
System offset is not offset on the image display.
• When marking data is inside of marking field on image display screen and the error “Existed marking data outside of
marking field” is displayed. Check the setting value in system offset.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...