144
Step & Repeat
This “Step & Repeat” applies for marking the same content repeatedly. It is usable for marking object laid side by side such
a palletized object.
Reference
•
For LP-M and LP-Z series, when the “3D” on the “2D/3D setting” of the common condition on for the general condition is
checked ON, the Step & Repeat marking becomes invalid.
1
2
4
3
5
7
8
6
Description
1
Step-Repeat (Step & Repeat Marking) :
Check this box to validate the Step & Repeat marking function.
2
Number of Row :
Number of Column :
The number of rows / columns where the pattern which has been set is to be marked.
Setting Range
1 to 400
Reference
•
The pattern is the unit of data created in Step & Repeat.
•
Max. number of settable patterns is 4000.
3
Row Step :
Column Step :
The pitch between patterns in row / column direction.
Setting Range
0.000 to 120.000 mm (LP-M500 / LP-Z130)*
0.000 to 90.000 mm (LP-S500)*
4
Base Position :
Specifies the position of reference pattern for step & Repeat marking.
Select the position among [Upper L], [Upper R], [Lower L], [Lower R].
5
X/Y Offset :
Shifts the object to X/Y direction. This coordinate is applied to the origin of the base object.
Setting Range
-60.000 to +60.000 mm (LP-M500 / LP-Z130)*
-45.000 to +45.000 mm (LP-S500)*
*
For the setting range of the other model, refer to “Input Setting Value by Series” (P.296).
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...