![background image](http://html1.mh-extra.com/html/panasonic/kx-vc300/kx-vc300_operating-instructions-manual_3638168136.webp)
Message
Cause and Solution
Invalid SIP Server Address.
•
The format of the entered SIP server address is invalid.
→
Enter the SIP server address correctly, in the format
XXX.XXX.XXX.XXX (decimal values separated by periods).
For values of only 1 or 2 digits, enter these numbers as they are. Do
not enter like [.001].
Example: The IP address is [192.168.0.1].
–
Correct entry: [192.168.0.1]
–
Wrong entry: [192.168.000.001]
Multicast or broadcast addresses cannot be used.
Invalid SIP Domain Name.
•
The format of the entered SIP domain name is invalid.
→
Enter an RFC-compliant value. For details, contact your network
administrator.
Saving log failed.
•
You are using a USB memory device that is not compatible with the
unit.
→
Use a USB memory device compatible with the unit (Page 110).
•
There is not enough free space on the USB memory device you are
using.
→
Confirm the USB memory device has sufficient free space (at least
5 MB) before using it.
Invalid Operation.
Initial setting is not completed.
•
In local site settings, you tried to select and save a connection mode
without completing network settings.
→
Before making local site settings, change the connection mode
(Page 105) and make network settings (Page 89).
Input DNS Server address.
•
You tried to update the software (Page 108) without a DNS server set.
→
In network settings (Page 89) (or local site settings when a local site is
selected [Page 111]), set either
"DNS Server"
or
"Primary DNS
Server"
.
Note
•
When
"DNS Server"
is set to
"Auto"
, the DHCP server may be the
cause of the problem. In this case, contact your network
administrator.
System Error!
Please restart the system.
If error message appears
again, please contact Installer
or Service Administrator.
•
The unit’s internal software failed to start up.
•
The unit failed to write data to the internal flash memory.
→
Reset the unit by turning off its power, then turning it back on. If the
same message is displayed after resetting the unit, contact your dealer.