2.7 [1] Configuration
142
PC Programming Manual
Status Receive
Selects what happens to a call when the Status Message from the network does not match the actual
status of the call.
Default
Ignore
Value Range
Ignore: Ignore the Status Message from the network.
Disconnect: Disconnect the call.
Maintenance Console Location
2.7.14 [1-1] Slot—PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Line Coding
Selects the line coding type of the PRI PCM (Pulse Code Modulation) for the port.
Default
B8ZS
Value Range
B8ZS, AMI
Maintenance Console Location
2.7.14 [1-1] Slot—PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Frame Sequence
Selects the type of frame sequence for the port.
Default
Extend Multi frame (ESF)