2.7 [1] Configuration
PC Programming Manual
119
Maintenance Console Location
2.7.11 [1-1] Slot—LCO Port
Programming Manual References
None
Feature Manual References
1.4.2 Dial Mode Selection
CPC Signal Detection Time—Outgoing, Incoming
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming CO
line calls before disconnecting the line. When
None
is selected here, the line will not be disconnected
when a CPC signal is not detected.
Default
400 ms
Value Range
None, 6.5 ms, 8 × n (n=1–112) ms
Maintenance Console Location
2.7.11 [1-1] Slot—LCO Port
Programming Manual References
None
Feature Manual References
1.3.20 CPC (Calling Party Control) Signal Detection
DTMF Width
Selects the length of the DTMF tone sent to the analog CO line.
Default
80 ms
Value Range
80 ms, 160 ms
Maintenance Console Location
2.7.11 [1-1] Slot—LCO Port
Programming Manual References
None
Feature Manual References
None