2.3 Connect
38
PC Programming Manual
Connection Settings for RS-232C
Setting
Values
Explanation
Port
COMx
Specify the number of the COM port assigned
to the PC's RS-232C interface. Only available
COM ports are displayed.
Baud Rate (bps)
2400bps, 4800bps,
9600bps, 19200bps,
38400bps, 57600bps,
115200bps
Specify the speed of data transmission.
Connection Settings for Modem
Setting
Values
Description
Dial Number
1-9, 0, *, #, "," [comma],
T, P, W*
1
Enter the telephone number to be dialed to
access the PBX.
T: Converts the
Dial Type
from Pulse to Tone.
"," [comma], P, W: Inserts a pause.
Dial Type
Auto(Tone),
Auto(Pulse), Manual
Specify the outgoing dialing method.
If
Manual
is chosen, dialing must be done with
a connected telephone.
Comment
–
Enter a comment to identify the set of values.
Port
COMx
Specify the number of the COM port assigned
to the PC's modem interface.
Only available COM ports will be displayed.
Baud Rate
1200bps, 2400bps,
4800bps, 9600bps,
19200bps, 38400bps
Specify the speed of data transmission.
Modem Initialize
–
Enter the modem initialize command, and click
Initialize
to send the command to the modem.
For more details, refer to your modem's
instruction manual.
*
1
: T, P and W can only be entered when using MPR Software File Version 3.2000 or later.
Connection Settings for LAN
Setting
Values
Explanation
IP Address
1.0.0.0–
223.255.255.255
Specify the IP address of the PBX on the LAN.
Enter the same IP address that was input in
IP
Address
of
2.7.28 [1-1] Slot—CTI-LINK Card
Property (KX-TDA100/KX-TDA200/KX-
TDA600 only)
.