2.1 Introduction
20
PC Programming Manual
2.1.2
Access Levels
There are three main levels of access to the Maintenance Console: User, Administrator and Installer.
Each level has its own Programmer Code, which must be entered to run the Maintenance Console.
The allowed format for each programmer code is as follows:
Access to menu options within the Maintenance Console is restricted depending on the Programmer
Code, and the current software mode (see
2.1.1 Starting Maintenance Console and Software
Modes
). When a menu option is limited to certain access levels, this is noted in this manual in the
initial description of that menu option, for example:
"This option is only available at Installer level."
If a sentence like this does not appear under the heading, the menu option is available at all levels.
The target users for each access level are as follows:
The options available in each mode and access level are shown below.
The access levels are abbreviated as follows:
U: User; A: Administrator; I: Installer
A check mark indicates that the menu option is available for that access level.
Connection Settings for LAN
Setting
Values
Explanation
IP Address
1.0.0.0–
223.255.255.255
Specify the IP address of the PBX on the LAN.
Enter the same IP address that was input in
IP
Address
of
2.7.28 [1-1] Slot—CTI-LINK Card
Property (KX-TDA100/KX-TDA200/KX-
TDA600 only)
.
Port Number
10000–65535
Specify the port number used to access the
PBX via LAN. Enter the same port number that
was input in
Maintenance Port Number
of
2.7.28 [1-1] Slot—CTI-LINK Card Property
(KX-TDA100/KX-TDA200/KX-TDA600 only)
or
2.7.19 [1-1] Slot—IP-GW Card Property
(KX-TDA50 only)
.
Item
Length
User Level Programmer Code
0 – 16 characters
Administrator Level Programmer Code
4 – 16 characters
Installer Level Programmer Code
4 – 16 characters
Access Level
User
User
For end users
Administrator
For system administrators
Installer
For dealers and system installers