Feature
Description
Log-in/Log-out Monitor and
Remote Control
Monitor:
The supervisor extension can monitor the log-in/log-out
status of the incoming call distribution group members through the
corresponding DSS button light.
Remote Control:
The supervisor extension can change the
status of the members by pressing the corresponding DSS button.
[Example]
--- Date and time
--- ICD group's floating extension number and name
--- Number of calls waiting in the queue
--- Elapsed waiting time of the call queuing the longest
With
<Incoming Call Queue Monitor Display>
<Log-in/Log-out Monitor/Remote Control Mode with DSS Button light>
JAN.31 08:13AM FRI
601:Sales Section
Waiting Calls Now :00006
Max. Waiting Time :05'10
EXIT LOG SPRVS
Log-in/Log-out Monitor
DSS buttons show the status
of the corresponding group
members.
Log-in/Log-out Remote Control
Pressing a DSS button
changes the extension's
status as follows:
Light pattern
Green on
Slow Green Flashing
Red on
Off
Status
Log-in (Ready)
Log-in (Not Ready)
Log-out
Light pattern
Red on
Green on
Status
Log-out
Log-in (Ready)
Since JAN.29 09:10AM
Total Calls :00996
Overflow Calls :00131
Lost Calls :00039
Average Waiting :02'12
EXIT CLEAR
JAN.31 08:13AM FRI
601:Sales Section
Waiting Calls Now :00006
Max. Waiting Time :05'10
EXIT
--- Monitoring starting date and time
--- Total number of incoming calls
--- Total number of overflowed calls
--- Total number of lost calls
--- Average queuing time
Extension in another ICD
group
Conditions
•
Available Extension as a Supervisor Extension
a.
One supervisor extension can be assigned for each incoming call distribution group, but it need not
belong to the group.
b.
One extension can be the supervisor extension of more than one incoming call distribution group.
•
Available Paired DSS Console
This feature is available for the KX-T7640, KX-T7440, KX-T7441, KX-DT390, and KX-DT590.
•
Accumulation Value Clear
Accumulation value data (total incoming calls, total overflowed calls, lost calls, average queuing time) can
be cleared manually. The date and time of clearing is saved and is shown on the display (monitoring starting
date and time). When the value exceeds 99999 before clearing, "****" will be shown.
190
Feature Manual
Document Version 2016-03
10.1.7 ICD Group Features—Supervisory
Summary of Contents for KX-NS1000
Page 15: ...Section 1 For Your Safety Document Version 2016 03 Feature Manual 15...
Page 18: ...18 Feature Manual Document Version 2016 03 1 1 1 For Your Safety...
Page 19: ...Section 2 Features and Configurations A Document Version 2016 03 Feature Manual 19...
Page 36: ...36 Feature Manual Document Version 2016 03 2 1 8 Automatic Time Adjustment...
Page 37: ...Section 3 Features and Configurations B Document Version 2016 03 Feature Manual 37...
Page 44: ...44 Feature Manual Document Version 2016 03 3 1 2 BGM Background Music...
Page 45: ...Section 4 Features and Configurations C Document Version 2016 03 Feature Manual 45...
Page 89: ...Section 5 Features and Configurations D Document Version 2016 03 Feature Manual 89...
Page 122: ...122 Feature Manual Document Version 2016 03 5 1 18 DSP Resource Usage...
Page 123: ...Section 6 Features and Configurations E Document Version 2016 03 Feature Manual 123...
Page 137: ...Section 7 Features and Configurations F Document Version 2016 03 Feature Manual 137...
Page 159: ...Section 8 Features and Configurations G Document Version 2016 03 Feature Manual 159...
Page 165: ...Section 9 Features and Configurations H Document Version 2016 03 Feature Manual 165...
Page 172: ...172 Feature Manual Document Version 2016 03 9 1 6 Hot Line...
Page 173: ...Section 10 Features and Configurations I Document Version 2016 03 Feature Manual 173...
Page 217: ...Section 11 Features and Configurations K Document Version 2016 03 Feature Manual 217...
Page 220: ...220 Feature Manual Document Version 2016 03 11 1 1 KX UT Series SIP Phones...
Page 221: ...Section 12 Features and Configurations L Document Version 2016 03 Feature Manual 221...
Page 228: ...228 Feature Manual Document Version 2016 03 12 1 4 Local Alarm Information...
Page 229: ...Section 13 Features and Configurations M Document Version 2016 03 Feature Manual 229...
Page 237: ...Section 14 Features and Configurations O Document Version 2016 03 Feature Manual 237...
Page 252: ...252 Feature Manual Document Version 2016 03 14 1 9 Operator Features...
Page 253: ...Section 15 Features and Configurations P Document Version 2016 03 Feature Manual 253...
Page 331: ...Section 16 Features and Configurations Q Document Version 2016 03 Feature Manual 331...
Page 333: ...Section 17 Features and Configurations R Document Version 2016 03 Feature Manual 333...
Page 340: ...340 Feature Manual Document Version 2016 03 17 1 3 Room Status Control...
Page 341: ...Section 18 Features and Configurations S Document Version 2016 03 Feature Manual 341...
Page 364: ...364 Feature Manual Document Version 2016 03 18 1 12 Syslog Record Management...
Page 365: ...Section 19 Features and Configurations T Document Version 2016 03 Feature Manual 365...
Page 385: ...Section 20 Features and Configurations U Document Version 2016 03 Feature Manual 385...
Page 443: ...Section 21 Features and Configurations V Document Version 2016 03 Feature Manual 443...
Page 448: ...448 Feature Manual Document Version 2016 03 21 1 2 Virtual PS...
Page 449: ...Section 22 Features and Configurations W Document Version 2016 03 Feature Manual 449...
Page 459: ...Section 23 Appendix Document Version 2016 03 Feature Manual 459...
Page 481: ...Document Version 2016 03 Feature Manual 481 Notes...