FP3 MEWNET - TR
Chapter4 - 2. Page.61
57
4-2. I/O Allocation
1. I/O Allocation and Station Number Setting
J
When using only FP I/O transmitter units as slave stations
Example 1: When configuring a system with 4-point type units
32 inputs:
X0 to X1F
32 outputs:
Y20 to Y3F
Operation mode selector
X0 to X3
No. 0
X8 to XB
X10 to X13
Y20 to Y23
Y28 to Y2B
No. 1
No. 2
No. 0
No. 1
Slave stations (all FP I/O transmitter units)
4 - input
type
4 - input
type
4 - input
type
4 - output
type
4 - output
type
Station
number
Each 4 - point type unit, slave
station is allocated with 8 points.
The latter 4 points (X4 to X7)
cannot be used.
Set station numbers 0
through 3 for both input
and output type units.
FP3 transmitter master unit
0
1
2
3
4
FP3/
FP10S
CPU
Power
supply unit
OFF
ON
1
2
3
4
5
6
7
8
ON
OFF
ON
OFF
Example 2: When configuring a system with 8-point type units
Slave stations (all FP I/O transmitter units)
8 - input
type
8 - input
type
8 - input
type
8 - output
type
8 - output
type
Station
number
X0 to X7
X8 to XF
X10 to X17
Y20 to Y27
Y28 to Y2F
No. 0
No. 1
No. 2
No. 0
No. 1
This 8 - point type slave station is allocated with 8 points.
32 inputs:
X0 to X1F
32 outputs:
Y20 to Y3F
Operation mode selector
FP3 transmitter master unit
0
1
2
3
4
FP3/
FP10S
CPU
Power
supply unit
OFF
ON
1
2
3
4
5
6
7
8
ON
OFF
ON
OFF