FP3 MEWNET - TR
Chapter4 - 1. Page.55
51
x
Selector numbers 3 and 4:
Not used
x
Selector numbers 5 to 8:
I/O point selection
The I/O points to be used by slave stations are selected by operation mode selector
numbers 5 through 8.
See page 57, “4 -2. I/O Allocation,” for details about I/O allocation setting and
allocation patterns.
I/O points
Allocation pattern number
Selector number
Input
Output
Allocation pattern number
5
6
7
8
128
128
Pattern No. 1
ON
ON
ON
ON
128
64
Pattern No. 2
ON
ON
OFF
ON
128
32
Pattern No. 3
ON
ON
ON
OFF
128
0
Pattern No. 4
ON
ON
OFF
OFF
64
128
Pattern No. 5
OFF
ON
ON
ON
64
64
Pattern No. 6
OFF
ON
OFF
ON
64
32
Pattern No. 7
OFF
ON
ON
OFF
64
0
Pattern No. 8
OFF
ON
OFF
OFF
32
128
Pattern No. 9
ON
OFF
ON
ON
32
64
Pattern No. 10
ON
OFF
OFF
ON
32
32
Pattern No. 11
ON
OFF
ON
OFF
32
0
Pattern No. 12
ON
OFF
OFF
OFF
0
128
Pattern No. 13
OFF
OFF
ON
ON
0
64
Pattern No. 14
OFF
OFF
OFF
ON
0
32
Pattern No. 15
OFF
OFF
ON
OFF
Note:
x
Since the FP3 transmitter master unit has no selector for terminal station setting, it must be located on the
network as a terminal.
2) Operation mode when shipped
x
The operation mode selector numbers are all set to the OFF position when shipped.
x
Operation mode setting when shipped:
- The unit is used as a MEWNET -TR master station.
- When an abnormality occurs during operation, all slave stations stop I/O control.
- The I/O points used are as follows:
Input: 0 point, Output: 0 point
x
When the power supply is turned ON under these conditions, an error occurs.
4 -1. Operation Mode Setting