ELC500 Control unit
64
Item
Description
(h)
Wait time to sending
Set wait time for sending next command after receiving a
response.
<Initial> 2000 x 0.01ms
<Set range> 0 to 20000
(i)
Header STX
Set Header code
<Initial> Unavailable
<Set range> Available / Unavailable
(j)
Terminator setting
Set terminator conditions
<Initial> CR
<Set range> CR / CR+LF / Time / ETX
(k)
Time to wait terminator
*6
Set time to judge a terminator.
<Initial> 0 x0.01ms
<Set range> 0 to 10000
*1 In case of using FPWIN Pro7 to make communication program.
*2 Only when selecting COM1.
*3 In case of using as a master, it is necessary to make communication program by FPWIN Pro7.
*4 Set range differs according to communication protocol.
*5 In case of select MODBUS RTU master/slave, data length is fixed to 8bit.
*6 Only when selecting time for terminator setting.
■
Communication protocol: PLC link
Item
Description
(a)
Usage
Set usage for serial communication.
<Initial> Data collection(ELC)
<Set range> Data collection(ELC) / Program control(PLC)
(b)
Protocol
Set communication protocol.
<Initial> MEWTOCOL-COM master/slave
<Set range>
MEWTOCOL-COM master/slave
MEWTOCOL7-COM slave
MODBUS RTU master/slave
General communication
PLC link
(c)
Unit No.
Set unit number of ELC500 to connect PLC link.
<Initial> 1
<Set range> 1 to 16
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)