Section 400-Programming
Introduction to DBS 576 Programming
576-13-400
DBS 576 (USA) issued 05/20/98
●
Intro-25
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1 0 05 0017 Hold (0-7) Hold
RAI Serial Port: Data Format
5 (8bits/NoPar./
1stop)
1-83
FF1 0 05 0018 Hold (0-5) Hold
RAI Serial Port: Baud Rate
5 (9600 bps)
1-83
FF1 0 05 0019 Hold (0-2) Hold
RAI Serial Port: Protocol
0 (No order)
1-84
FF1 0 05 0020 Hold (0 or 1) Hold
RAI Serial Port: Echo Control
0 (Off)
1-84
FF1 0 05 0021 Hold (1-255) Hold
RAI Serial Port: Maximum Input Digits
1 digit
1-85
FF1 0 05 0033 Hold (0-7) Hold
Serial Port 2: Data Format
5 (8bits/NoPar./
1stop)
1-85
FF1 0 05 0034 Hold (0-5) Hold
Serial Port 2: Baud Rate
5 (9600 bps)
1-86
FF1 0 05 0035 Hold (0-2) Hold
Serial Port 2: Protocol
0 (No order)
1-86
FF1 0 05 0036 Hold (0 or 1) Hold
Serial Port 2: Echo Control
0 (Off)
1-87
FF1 0 05 0037 Hold (1-255) Hold
Serial Port 2: Maximum Input Digits
80 digits
1-87
FF1 0 06: Serial Port Output Data
1-88
FF1 0 06 0001 Hold (0-2) Hold
SMDR Data to Serial Port
1 (Port 1)
1-88
FF1 0 06 0002 Hold (0-2) Hold
Fault Alarm Data to Serial Port
0 (None)
1-88
FF1 0 06 0003 Hold (0-2) Hold
Programmed Data to Serial Port
2 (Port 2)
1-89
FF1 0 06 0004 Hold
Not Used
--
1-89
FF1 0 06 0005 Hold (0-2) Hold
Bus Monitor Data to Serial Port
2 (Port 2)
1-90
FF1 0 07 and 08: PBX Parameters
1-91
FF1 0 07 (0001-0012) Hold (0-16) Hold
Auto Pause Position Behind PBX
1 (after 1st digit,
for ”9”)
0 (None, for all
other digits)
1-91
FF1 0 08 (0001-0006) Hold FLASH (0-
9999) Hold
PBX Trunk Access Codes
Code 1: 9
Codes 2-6: none
1-92
FF1 0 09: SMDR Output Format
1-93
FF1 0 09 0001 Hold (0-2) Hold
SMDR Output Format
1 (Format #1)
1-93
FF1 0 10 and 11: Call Restriction Between COS
1-94
FF1 0 10 (00-15) (01-16) Hold (0 or 1)
Hold
Call Restriction Between Extension COS
0 (Allowed)
1-94
FF1 0 11 (00-15) (01-16) Hold (0 or 1)
Hold
Call Restriction Between Trunk COS
0 (Allowed)
1-95
FF1 0 12, 13, and 14: MOH Source
1-96
FF1 0 12 (0001-0072) Hold (0-3) Hold
MOH Source for CO Trunks
0 (Internal single
tone)
1-96
FF1 0 13 (0001-0072) Hold (0-3) Hold
MOH Source for Tie-Lines
0 (Internal single
tone)
1-97
FF1 0 14 (0001-0072) Hold (0-3) Hold
MOH Source for Intercom Calls
0 (Internal single
tone)
1-98
FF1 0 15, 16, and 17: SSD Blocks
1-99
FF1 0 15 (0001-0072) Hold (0-72) Hold
SSD Block Assignment to MCO Tenant
Groups
1 (SSD Block 1)
1-99
FF1 0 16 0001 Hold (0-800) Hold
SSD Common Block for MCO Tenant Groups 0 (none)
1-100
FF1 0 17 (0001-0144) Hold (0-799 or 0-
800) Hold
SSD Block Assignment
See table, page
1-101
1-100
FF1 0 18: Synchronized Clock
1-103
FF1 018 (0001-0003) Hold (BSS/C) Hold
Synchronized Clock
--
1-103
FF1 0 19: TRS Class for Forced Account Codes
1-104
FF1 0 19 0001 Hold (1-50) Hold
TRS Class for Forced Account Codes
TRS Class 1
1-104