Section 400-Programming
FF2: Trunk Programming (Analog CO)
576-13-400
DBS 576 (USA) issued 05/20/98
●
Page 2-11
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
Notes:
Typically, COs in the U.S. do not send reverse signaling for called-party answer (set this address to “1”).
The Call Duration Timer for Outbound CO Calls will not work on this trunk if the above address is
set to “0” (reverse signal from CO), and the trunk’s Call Duration setting is set to “1” (use system
timer).
Related Programming:
Call Duration (pg. 2-19) FF2 0 BSSC 02 03 Hold (0 or 1) Hold
Call Duration Timer (analog CO) (pg. 1-118) FF1 1 01 0005 Hold (1-255) Hold
Not Used
(all CPCs) - Version 1.0 or higher
FF2 0 BSSC 01 06 Hold
FF2 0 BSSC 01 07 Hold
FF2 0 BSSC 01 08 Hold
$
)! B
$%
)! B
$
)! B
Reverse Answer Signal Control
(all CPCs) - Version 1.0 or higher
(not used in U.S.) Set whether the CO sends back reverse signaling when the
called party answers an outgoing call on this trunk.
FF2 0 BSSC 01 09 Hold (0 or 1) Hold
BSSC: Analog (CO) Trunk Position
B=Cabinet no. 1-6
SS=Slot no. 01-12
C=Circuit no. 1-8
0=Reverse signal from CO.
1=No reverse signal from CO. (default)
$&
( /) 1