FF2: Trunk Programming (T1 CO)
Section 400-Programming
Page 2-88
●
DBS 576 (USA) issued 05/20/98
576-13-400
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
Related Programming:
Disconnect Detect (pg. 2-88) FF2 2 BSSCC 02 01 Hold (0 or 1) Hold
Dial Pulse Minimum Pause (pg. 2-88) FF2 2 BSSCC 02 02 Hold (0 or 1) Hold
Ground Start Ring Type (pg. 2-89) FF2 2 BSSCC 02 03 Hold (0 or 1) Hold
DID Ring Detect Timer (pg. 2-89) FF2 2 BSSCC 02 04 Hold (0 or 1) Hold
Disconnect Supervision Timer (pg. 2-95) FF2 2 BSSCC 02 12 Hold (0-3) Hold
Guard Timer for Outbound Calls (pg. 2-96) FF2 2 BSSCC 02 13 Hold (0-3) Hold
Inbound Ground Detect Timer (pg. 2-96) FF2 2 BSSCC 02 14 Hold (0-3) Hold
Notes:
This setting is available only if the Trunk Signal Type is set for “0” (Loop Start) or “1” (Ground Start);
it is not available for DID signaling types.
Related Programming:
Trunk Signal Type (pg. 2-87) FF2 2 BSSCC 02 00 Hold (0-3) Hold
Disconnect Supervision Timer (pg. 2-95) FF2 2 BSSCC 02 12 Hold (0-3) Hold
Disconnect Detect
(all CPCs) - Version 1.0 or higher
Enable/Disable system detection of disconnect signal sent by the CO if the
outside party disconnects first.
FF2 2 BSSCC 02 01 Hold (0 or 1) Hold
0=No detection of disconnect signal
BSSCC: T1 (CO) Channel Position
B=Cabinet no. 1-6
SS=Slot no. 01-12
CC=Channel no. 01-24
from CO. (default)
1=System will detect disconnect signal.
$
'
Dial Pulse Minimum Pause
(all CPCs) - Version 1.0 or higher
Set the minimum pause time for dial-pulse signaling.
FF2 2 BSSCC 02 02 Hold (0 or 1) Hold
0=625 ms (default-US) or
BSSCC: T1 (CO) Channel Position
B=Cabinet no. 1-6
SS=Slot no. 01-12
CC=Channel no. 01-24
750 ms (default-UK)
1=1000 ms
$
$ 2)@$-