background image

Making Communication Easy. 

Aristel AV Series
Programming

 Manual

Summary of Contents for AV SERIES

Page 1: ...Making Communication Easy Aristel AV Series Programming Manual ...

Page 2: ... 140 ex GST 140 ex GST 90 ex GST This form must be printed from this manual and sent via fax before any service work can be scheduled or completed Rates are also excluding any materials required ...

Page 3: ...Aristel Networks PROGRAMMING MANUAL FOR THE AV SERIES KEY SYSTEMS AV12 20 38 256 MODELS ...

Page 4: ...n nu ua al l f fo or r A AV V 1 12 2 2 20 0 3 38 8 a an nd d 2 25 56 6 s sy ys st te em ms s This manual is current for the following AV software versions AV12 O01r AV20 O01e AV38 O05h AV256 MPU O08 IPU V251 This Manual is Version AV 2 1 Issued June The following changes were made for this update ...

Page 5: ...Timeout 12 Zone 117 DISA No Dial Timeout 12 Zone 118 DISA Delay Time 12 Zone 119 DISA CO Time 13 Zone 120 AT RED Wait Time 13 Zone 121 AT Red Pause Time 13 Zone 122 Busy Rem ICM Time 13 Zone 123 In Hunt Ring Time 13 Zone 124 Door SensorR Time 13 Zone 125 Busy Tn On1 Time 14 Zone 126 Busy Tn Off1 Time 14 Zone 127 Busy Tn On2 Time 14 Zone 128 Busy Tn Off2 Time 14 Zone 129 Swon Delay Time 14 Zone 130...

Page 6: ... 23 Zone 227 Name SPD 23 Zone 228 SMDR Masked 24 Zone 229 Slt Busy Rem 25 Zone 230 Link Monitor 25 Zone 231 Volume Initi VAL 25 Zone 232 B B C Pause TIMES 26 Zone 233 Busy Tn Tms 26 Zone 234 Co Auto Trf 26 Zone 235 System PSW 27 Zone 236 Dial Tn Tms 27 Zone 237 Slt Pulse 27 Zone 238 DISA Group 27 Zone 239 DND Disable 27 Zone 240 Auto Co Dis 27 Zone 241 Direct Dial 28 Zone 242 Xhold 29 Zone 243 S O...

Page 7: ... Group 1 of 8 groups 46 Zone 501 DSS GP Group 1 of 8 Groups 49 Zone 502 Port No Port No System port number for the station 50 Zone 503 Station Gp Ext Extension number 51 Zone 504 Station Functions 1 Ext Extension number 51 Zone 505 Station Function 2 Ext Extension number 53 Zone 506 Station Function 3 Ext Extension number 54 Zone 507 Station Function 4 Ext Extension number 55 Zone 508 HOT CO Ext E...

Page 8: ...Entering System Programming On Hook Programming Note Using the programming overlay will minimize any confusion regarding the save key on 15 and 25 button keyphones Step 1 Handset on Hook Step 2 Press FUNC System will ask for Programming Password Step 3 Enter Programming Password If password is not set then ignore this step Step 4 Press SAVE Press FAC if using a 15 Button Keyphone Step 5 If the sys...

Page 9: ...w each programming zone DSS23 Clear the current digit to p Pause DSS24 Clear the current digit to T Tone DSS25 Saves the setting data to the system s memory KP10X Handset series DSS Keys Function DSS1 Back to the previous Program Zone DSS2 Forward to the next Program Zone DSS3 Shifts cursor left DSS4 Shifts cursor right DSS5 Changes the Function Condition DSS6 Help key Used to review each programm...

Page 10: ...S BUTTON LAYOUT AND PROGRAMMING FUNCTIONS DSS 16 FN 028 PAGE ALL RED ONLY DSS 17 FN 005 FAC RED ONLY DSS 18 FN 006 FWD RED ONLY DSS 19 FN 044 PICK UP RED ONLY DSS 20 Save FN 004 SAVE RED ONLY DSS 11 Save EXT 15 RED GREEN DSS 12 Tone EXT 16 RED GREEN DSS 13 Pause EXT 17 RED GREEN DSS 14 Don t Care EXT 18 RED GREEN DSS 15 Clear Digit FN 071 DOOR RED GREEN DSS 6 Help EXT 11 RED GREEN DSS 7 EXT 12 RED...

Page 11: ...Press FUNC 25 butt DSS 21or 15 butt DSS 6 to enter Programming Help List Step 3 Press SAVE key during Help List for direct access to the system s programming in the same zone area Press FAC if using a 15 Button Keyphone The system s data can then be altered Note Altering the system data is allowed only if the system is not password protected Function Keys Used During Programming Help List Function...

Page 12: ...ss DSS Direct Station Selection Key DTMF Dual Tone Multi Frequency Tone Dialing ECF External Call Forward Func Function key on key telephone HF Hands Free Item Cursor position on station display or Zone feature to be programmed KP Keyphone LCD Liquid Crystal Display LED Light Emitting Diode ODD One Digit Dialing Off Hook Hand piece out of cradle position On Hook Hand piece in cradle position SMDR ...

Page 13: ... 256 Default value 011 for AV12 Range 000 255 x 6 mSec This sets the minimum on hook time to be recognized as a hook flash If this time is not reached on hook no action is taken by the system If the time is exceeded and is less than the time set in Zone 102 the call will be placed in hold Related Zones Z102 Zone 104 Ring On Time Default value 006 Range 000 255 x 40 mSec This defines the ring sound...

Page 14: ...Sec If an Exclusive held call reverts to the holding station and is not answered by the time set in this zone it will transfer to an available console in the same console group Related Zones Z109 Z242 Z122 Z505 Item 03 Zone 111 SLT DT Timeout Default value 005 Range 000 255 Sec SLT If the SLT is off hook for more than the set time and no digits are dialed dial tone will cease and the SLT is connec...

Page 15: ...divert back to the original station Related Zones Z113 Zone 115 CFW NoAns Tr Time Default value 005 Range 000 255 Sec If a station is programmed for Call Forward on No Answer an incoming or internal call to that station will be call forwarded after the time setting has been reached Related Zones Z109 Z242 Zone 116 DISA No Ans Timeout Default value 025 Range 000 239 Sec When an incoming DISA call i...

Page 16: ...minder tone will be heard at intervals set by this timer If the station is a 25 Button Keyphone the tone will be heard from the base of the Keyphone If the station is a 15 Button Keyphone or an SLT the tone will be heard in the earpiece of the handset Setting this zone to 000 will stop the Busy Reminder Tone This zone also sets the time between rings when a call is recalling from on hold exclusive...

Page 17: ... Zone 128 Busy Tn Off2 Time Default value 012 Range 000 255 20 mSec Zone 127 and Zone 128 define a second example of the carrier s busy tone cycle so the system can recognize busy tone Zone 127 is the duration of tone on and Zone 128 is the duration of silence in the cycle Related Zones Z109 Z127 Z242 Zone 129 Swon Delay Time Default value 003 Range 000 255 40 mSec This timer is the duration taken...

Page 18: ...he second page button has been pressed Pressing the second page button will immediately return the station to the first page state Related Zones Z500 Z503 Item 2 and Item 8 Zone 135 Second Function Silent Time for Zone 212 Default value 060 Range 000 255 5 Sec Minimum value allowed 007 This timer sets the period between ringing for a normal SLT using the Message Waiting Function NOTE IF THE EXTENS...

Page 19: ... AV24 Default value 000 Range 000 255 1 Sec These Zones are not functional for the AV256 Related Zones None Zone 140 DISA Delay2 Default value 000 Range 000 255 1 Sec This Zone has the same function as Zone 139 Related Zones Zone 139 Zone 604 Item 02 Z614 Zone 141 DISA Delay3 Default value 000 Range 000 255 1 Sec This Zone has the same function as Zone 139 Related Zones Zone 139 Zone 604 Item 02 Z...

Page 20: ...es Z 604 Item 1 Zone 201 Operator Default value 0 Range 0 9 NOTE This zone must not be the same digit as Zone 202 This Zone allocates the digit to be dialed to access the console operator Related Zones Z 400 Z202 Zone 202 Dial 9 CO Default value 9 Range 0 9 NOTE This zone must not be the same digit as Zone 201 This Zone assigns the digit to be dialed when trying to access a free CO line Related Zo...

Page 21: ... 2 second ext 3 third ext etc 2 Dial the whole group as set in Zone 401 using Common Signalling Group1 dial 1 Group 2 dial 2 etc 3 Dial the group number 7 groups max and the calls are rotated through the group as set in Zone 401 in turn from Item 01 to 08 NOTE Only 1 2 3 4 5 7 and 8 can be used for single digit dialling 6 9 0 ARE NOT VALID EXTENSIONS NOR ARE THEY VALID EXTENSION GROUPS 6 IS THE BR...

Page 22: ...tation in the same Station Groupset in Zone 503 Item 1 0 Disable 1 Enable Related Zones Z 503 Item 1 Z508 Zone 211 Wake Up Call Default value 1 Range 0 1 This Zone allocates the Voice message 0 or BGM 1 for the Wake Up Call function Related Zones None Zone 212 SLT Msg Wait Sign Default value 1 Range 1 R 2 V Allows Message Waiting signal to be left for an SLT It will ring for the time set in Zone 1...

Page 23: ... SLT redial and Speed Dial functions AV256 Page announcement signal either multi tone or single tone warning 15 button keyphones only Related Zones Z129 Zone 217 CO Mute Default value 0 Range 0 D 1 E This Zone disables the use of an external DTMF generator on a Keyphone until after the third digit is dialed Related Zones None Zone 218 DISA Recall Default value 3 Range 0 3 This Zone enables disable...

Page 24: ...number is entered into Z400 07 04 the call will be transferred to that extension which can be Func 2 6 call forwarded OR If Z400 07 04 is set to 00 and Zone 400 group 04 00 00 00 00 the call will be ended OR If there is are extension s in Zone 400 group 04 the call will be transferred to those consoles NOTE If an internal call or a DISA call is diverted directed to the Consoles and if Zone 400 Gro...

Page 25: ...before the setting in Zone 507 Item 02 a warning tone will be heard This is followed by a continuous beeping 5 seconds later this will be heard only by the internal party unless it is an SLT in which case both parties will hear the tone When the Zone 507 Item 02 time has expired the call will be released 3 This is the same as in 2 With the exception that both parties will hear the tone 4 Reserved ...

Page 26: ...9 140 2 300 100 399 40 AV256 ZONE SETTING VALUE SYSTEM SPEED DIAL SETS INDIVIDUAL SPEED DIAL SETS 0 100 100 199 500 1 200 100 299 400 2 300 100 399 300 3 400 100 499 200 4 500 100 599 100 4 5 6 7 8 9 SAME AS 4 SAME AS 4 Related Zones Z227 Z253 Z404 Z509 Zone 226 SPD Unrest Range Default value 000 000 Range aaa bbb This Zone sets the range of speed dial numbers that will be exempt from restrictions...

Page 27: ... lieu of the calling name the following programming is required Zone 227 1 Zone 225 a number greater than 0 Zone 404 Code 201 has 234 Service The following chart is used by the system AV256 example Zone 610 Set used in Z610 Zone 611 Set used in Z611 Zone 404 Code data Code number used in Zone 404 234 001 14 001 234 201 The last digits of the called number are placed in a set in zone 610 and the sa...

Page 28: ... FITTED ZONE 229 5 TIME Z119 x 10 10 SEC BOTH PARTIES HEAR BEEP 5 SEC BOTH PARTIES HEAR MESSAGE CODE 07 CALL IS DISCONNECTED NO VSU ZONE 229 1 TIME Z119 x 1 10 SEC BOTH PARTIES HEAR BEEP 5 SEC BOTH PARTIES HEAR BEEP CALL IS DISCONNECTED NO VSU ZONE 229 4 TIME Z119 x 10 10 SEC BOTH PARTIES HEAR BEEP 10 SEC ONLY B PARTY HEARS BEEP CALL IS DISCONNECTED NO VSU ZONE 229 5 TIME Z119 x 10 10 SEC BOTH PAR...

Page 29: ...ansfer is Disabled Manual operation if an SLT answers multiple incoming calls Answer first call Hook Flash to place first call on hold Answer second call Hook Flash to place second call on hold but retrieves first call and so on Auto Transfer is Disabled Zone 234 1 Zone 505 Item 05 0 or 1 As above but Auto Transfer is Enabled Zone 234 2 Zone 505 Item 05 0 or 1 Ext answers a call and Hook Flashes t...

Page 30: ...t Dialing as in Zone 401 but allows access to the groups set up in Zone 607 Related Zones Z607 Zone 239 DND Disable Default value 0 Range 0 D 1 E This Zone allows or disallows Do Not Disturb on a system wide basis and can over ride the DND button 0 Disable The system does have the Do Not Disturb function available 1 Enable The system does not have the Do Not Disturb function available Related Zone...

Page 31: ...BLE 05 NO 2 SEC Z602 group 01 AND group 02 YES RING HANDSET DISABLE 06 YES 2 SEC Z602 group 01 AND group 02 YES DISABLE 07 NO 2 SEC Z602 group 01 AND group 02 YES DISABLE 08 YES 2 SEC Z602 group 01 OR group 02 NO ENABLE 09 NO 2 SEC Z602 group 01 OR group 02 NO ENABLE 10 YES 2 SEC Z602 group 01 AND group 02 NO ENABLE 11 NO 2 SEC Z602 group 01 AND group 02 NO ENABLE Related Zones Z205 Z506 Item 06 Z...

Page 32: ...All unequipped CO lines must be locked in Zone 605 Related Zones Z136 Z303 Z402 Z404 Z605 Zone 244 Door SensorR Default value 0 Range 0 N 2 D This Zone sets the ringing mode used by the Door Sensor and Door Phone Note D Day N Night 0 1 2 3 4 5 Door Sensor D N N D D N N D Door Phone D N D N D N D N N D Related Zones Z124 Z131 Z249 Z602 Zone 245 SLT MSG FUN Default value 0 Range 0 D 1 E 0 Disable th...

Page 33: ...nge 0 D 1 E This Zone allows or disallows a console to program System Speed Dial numbers Name Speed Dial numbers and System Alarm 0 Disable 1 Enable Related Zones None Zone 251 RS232 MODEM Default value 0 NOTE Must be 3OR 5 for EH64 Hotel Motel working Range 0 R 1 M AV 256 AV 38 0 SMDR with no Meter Pulse detection 1 SMDR and 12 KHz Meter Pulse Detection 3 12KHz Meter Pulse Detection EH64 5 Timed ...

Page 34: ...lls general are to be metered every 4 minutes Local calls 10 1800 are free Local calls to 1900 are to be metered every 2 minutes Zone 251 5 enable time charging Zone 203 0 STD code Zone 140 240 time interval for non listed local calls Zone 141 030 time interval for non listed STD calls Zone 142 010 time interval for non listed ISD calls Zone 307 Item 01 0 free time before metering begins Zone 307 ...

Page 35: ...HEN DOWNLOAD THE NEW DATA TO THE SYSTEM The system will check for a match with the dialed number in items 1 to 8 and then if a match is found it will check to see if the time is in the operating band items 9 to 12 items 15 to 18 If 24 hour insertion is required enter 0000 for start and finish times If a full match is found the code in items 21 to 30 is inserted before the original number is dialed...

Page 36: ...lection or you can force selection of ISDN PSTN as desired Zone 253 enables disables the LCR function Zone 253 00 Digit insert LCR is disabled and Toll password is disabled Zone 253 03 CO select LCR and Toll password is disabled Zone 253 09 Digit insert LCR is enables and Toll password is disabled Zone 253 12 Digit insert LCR is enabled and Toll password is enabled Zone 225 must not be set to 0 or...

Page 37: ...ASH 7 0 Disable SLT places a call in hold by Hook Flash or pressing FLASH 1 Enable SLT places a call in hold by Hook Flash 7 or by pressing FLASH 7 Related Zones None Zone 255 VM PRE DIGIT Default value 8 Range 0 9 This Zone allocates the digit for activating the message waiting signal default 81 82 Related Zones Z245 Zone 256 MIDDAY FG Default value 0 Range 0 1 This Zone changes the Ext Toll laye...

Page 38: ...of the FAC call the restriction layer 6 will apply again NOTE If the 1st digit of the FAC is 9 then the normal restriction non FAC will apply during the FAC call Example Zone 257 1 FAC 9543 Zone 503 Extension 11 Item 05 6 22 If a FAC is used to initiate a call from ext 11 the call will be made and it will be restricted to layer 2 At the end of the FAC call the restriction layer 2 will apply again ...

Page 39: ...dddddddd Related Zones Z235 Various Zones are affected by the passwords Zone 302 Relay Fun Item relay number Default value 02 00 Range Relay 00 18 AV8 AV12 1 relay Item 01 AV16 AV20 AV24 AV38 2 relays Item 01 relay 1 Item 02 relay 2 AV256 16 relays 4 per cabinet maximum Items 01 to 16 This Zone sets the functions that the relay s will provide 00 No operation 01 Music on Hold 02 Door 1 Open 03 Door...

Page 40: ...ntinuously and will stop ringing only when the Sensor is returned to the normal condition S O S Alarm When the Sensor is triggered the system will make outgoing calls on all CO lines through the Speed Dial function according to Zone 243 and Zone 404 All engaged lines will be disconnected by the system To cancel S O S go off hook at a station and press 5 5 the password as set in Zone 301 Item 2 If ...

Page 41: ...and this time setting is reached The time is set as 5 Seconds this setting number 0 00 Seconds 01 05 Seconds 02 10 Seconds etc Item 02 Rec Incom The system will will not record all incoming calls 0 Do not record 1 Record Item 03 Rec Local Local calls will will not be recorded 0 Do not record 1 Record Item 04 Rec NoAns Incoming calls that are not answered will will not be recorded 0 Do not record 1...

Page 42: ...s call was made on CO 1 and lasted 5 mins 35 secs And was allocated to Account code 9125 Case 2 At 09 00 station 15 attempted a call on CO 5 but was disallowed by restriction Case 3 At 09 10 station 17 answered a DISA call on CO line 2 entered Account code 1111 and the call rang for 2 seconds with a duration of 5 mins 19 secs Case 4 At 10 00 an incoming call rang for 30 seconds without answer The ...

Page 43: ...is group is the group that night time DISA No Answer calls will be transferred to when Zone 219 Item 05 is enabled Group 7 ITEM 02 IS THE KEYPHONE EXTENSION TO BE USED FOR UNSUPERVISED REMOTE PROGRAMMING ITEM 04 IS THE CONSOLE FOR FUNC 2 6 CALL FORWARDING If Zone 218 is not 0 and after 3 attempts to transfer to a console are unsuccessful the call will be transferred to an SLT EXT that is the first...

Page 44: ...ANY GREETING MESSAGE 02 CALLED STATION IS BUSY MESSAGE 03 NON EXISTANT STATION NUMBER MESSAGE 04 ALL CONSOLES ARE BUSY MESSAGE 05 STATION DID NOT ANSWER MESSAGE 06 PLEASE HOLD THE LINE MESSAGE 07 UNSUCCESSFUL CALL ENDING MESSAGE 08 DISA FUNCTION CODE REQUEST MESSAGE 09 ENTER THE DISA FUNCTION PASSWORD MESSAGE 10 ACCESS TO PAGING PASSWORD MESSAGE 12 EXTERNAL CALL FORWARDING MESSAGE 16 2ND QUEUING M...

Page 45: ...ame to make a Speed Dial call Pressing DSS5 will toggle between the Code Name entry area the CO number entry area and the Name speed dial indicator N area The dial pad is used to input the letters for Named Speed Dial as follows A PRESS 2 B PRESS 2 2 C PRESS 2 2 2 D PRESS 3 E PRESS 3 3 F PRESS 3 3 3 G PRESS 4 H PRESS 4 4 I PRESS 4 4 4 J 5 K PRESS 5 5 L PRESS 5 5 5 M PRESS 6 N PRESS 6 6 O PRESS 6 6...

Page 46: ... 5 and Item 6 However it is possible to alter the levels of any CO line for any plan This will allow restrictions to be different for any one CO line depending on which plan group is being used Eg CO 1 could be 8 for plan 8 but CO 2 could be 0 for plan 8 This may provide extensive restriction capability but it is recommended that the default values be left in Zone 405 TOLL LEVEL RESTRICTIONS LAYER...

Page 47: ...rammer to set the system Common Disallowed Codes that no station except Toll level 0 unrestricted stations can dial Examples of Common Disallowed Codes 407 Disall 01 01 407 Allow 01 01 407 Allow 01 01 _ _ _ _ _ _ _ _ _ _ _ 077495544 060dddddddd No numbers are disallowed 077495544 is Disallowed Disallow any numbers All other numbers are starting with 060 Allowed to be dialed Related Zones Z405 Z503...

Page 48: ... to achieve Toll restrictions This zone applies to Toll Layers 4 and 6 Examples of Area Codes 410 Offi A 01 01 410 Offi A 01 01 410 Offi A 01 01 69d d _ _ _ _ _ Numbers starting with This should not be entered No numbers are Toll Code Office Code A Toll Code Area Code A Office Code A 69 are Office Code A calls any number is Office Code A Related Zones Z203 Z405 Z408 Zone 257 Zone 411 Offi B Code 1...

Page 49: ...ied AV12 Group 08 Not specified AV20 Group 01 25 Button KP10 Handset first page AV20 Group 02 25 Button KP10 Handset second page AV20 Group 03 15 Button White KP10X Handset first page AV20 Group 04 Not specified AV20 Group 05 22 Button KP70 Handset AV20 Group 06 Not specified AV20 Group 07 25 Button KP50 Handset AV20 Group 08 Not specified AV38 Group 01 25 Button KP10 Handset first page AV38 Group...

Page 50: ...00 AV12 22 FN043 FN043 FN043 00 AV12 23 FN009 FN009 FN009 00 AV12 24 FN044 FN044 FN044 00 AV12 25 FN004 FN004 FN004 00 AV20 1 CO 01 CO 01 CO 01 CO 01 CO 01 00 CO 01 00 AV20 2 CO 02 CO 02 CO 02 CO 02 CO 02 00 CO 02 00 AV20 3 CO 03 CO 03 CO 03 CO 03 CO 03 00 CO 03 00 AV20 4 CO 04 CO 04 CO 04 CO 04 CO 04 00 CO 04 00 AV20 5 FN070 FN070 FN080 FN080 FN003 FN070 FN071 FN070 AV20 6 11 11 FN003 00 11 00 11...

Page 51: ...V38 22 FN043 FN043 FN074 FN043 FN094 00 AV38 23 FN009 FN009 FN009 FN005 00 AV38 24 FN044 FN044 FN044 FN096 00 AV38 25 FN004 FN004 FN004 FN004 00 AV256 1 CO 01 CO 01 CO 01 CO 05 CO 01 11 00 00 AV256 2 CO 02 CO 02 CO 02 CO 06 CO 02 12 00 00 AV256 3 CO 03 CO 03 CO 03 CO 07 CO 03 13 00 00 AV256 4 CO 04 CO 04 CO 04 CO 08 CO 04 14 00 00 AV256 5 FN070 FN070 FN080 FN080 FN080 FN080 FN070 FN070 AV256 6 CO ...

Page 52: ...al 12 Security Code 46 Pick Up Group 80 1st to 2nd to 1st page 13 Temporary Security Number 47 Pick Up Group 1 81 Ringing Volume Level 14 Set Macro Function 48 Pick Up Group 2 82 Speaker Volume Level 15 Set Volume levels 49 Pick Up Group 3 83 Handset Volume Level 16 Individual Alarm Station 50 Pick Up Group 4 84 Ringing Frequency Ctrl 17 Individual Alarm Console 51 Pick Up Group 5 85 Auto Save Red...

Page 53: ... moves the cursor one place to the left and DSS4 moves the cursor one place to the right Item 02 KP Equipment What type of equipment is installed as the extension This allocates the type of equipment in use by the extension as per the chart below Equipment Number Equipment Function 0 No Equipment connected to the port 1 Key Telephone without LCD and Handsfree 2 Key Telephone with LCD and Handsfree...

Page 54: ...ion for the Daytime duration This allocates the Toll layer restriction level for the station during daytime hours Related Zones Z405 Item 06 Toll Night Sets the Toll as in Item 5 But this Item sets the Nighttime restriction This allocates the Toll layer restriction level for the station during nighttime hours Related Zones Z405 Item 07 Func26 Dis Enables or disables Func 2 6 external call forwardi...

Page 55: ...ne 302 or if a door station call is in progress AV8 12 AV16 20 24 38 1 Station Loud Bell for Relay 1 1 Station Loud Bell for Relay 1 2 Secret Recording for Relay 1 2 Station Loud Bell for Relay 2 3 Secret Recording for Relay 1 4 Secret Recording for Relay 2 AV256 1 Station Loud Bell for Relay 1 2 Station Loud Bell for Relay 2 3 Station Loud Bell for Relay 3 4 Station Loud Bell for Relay 4 5 Secret...

Page 56: ...ault 0 Related Zones Z400 Z503 Item 1 Item 05 Call Split Alternate call function See the System Administrator Manual for Conference Call Operation Alternate call operation for 2nd call incoming Alternate call operation for 2nd call outgoing 1 Place the first call on hold 1 Place the first call on hold 2 Go On Hook 2 Seize a free CO Line 3 Wait for the second call to ring the phone 3 Dial the wante...

Page 57: ...Volume UP Rising ringing for stations on incoming calls Allows or disallows the following function If an incoming call is not answered during the first ring signal the next ring signal will be at an increased volume The volume will continue to increase with each ring signal until either the call is answered or the maximum volume is reached 0 Disable 1 Enable Default 0 Related Zones None Item 05 IC...

Page 58: ...hat the FAC was entered under in Zone 403 Default 00 Related Zones Z403 Items 04 5 6 7 8 Reserved Reserved for future use These Zones have no function Default N A Related Zones None Zone 508 HOT CO Ext Extension number Default value 00 Range N A Forces the station to make an external or intercom call when the Handset is lifted For normal dialing the station must use the Spk button before selecting...

Page 59: ...gned station after the time in Zone 123 has been reached If both do not answer in the next period Zone 123 it will also ring the third assigned station This process continues until the call is terminated If an ext is to ring and is busy it can be programmed to receive BRT once only See Zone 604 notes AV256 ONLY If the Voice Service Card is used for a DISA line the Voice Channel number must be assi...

Page 60: ...RESS 5 5 L PRESS 5 5 5 M PRESS 6 N PRESS 6 6 O PRESS 6 6 6 P PRESS 7 Q PRESS 1 OR 7 7 R PRESS 7 7 7 S PRESS 7 7 7 7 T PRESS 8 U PRESS 8 8 V PRESS 8 8 8 W PRESS 9 X PRESS 9 9 Y PRESS 9 9 9 Z PRESS 11 OR 9 9 9 9 Item 01 CO Type Selects the CO line type for the system This zone informs the system what type of line is connected The options are 0 Centrex or Central Office Exchange line 1 PABX line 3 IS...

Page 61: ... the time set in Zone 119 This period can be extended by pressing any number button The call can be terminated by pressing the button Default 0 Related Zones Z116 Z117 Z118 Z119 Z218 Z219 Z301 Item 3 Z306 Z402 Z604 Item 4 Z609 Item 04 ECF Night External Transfer function This Zone allocates the Speed Dial Number that will be used for the ECF function 0 Disable ECF capability 1 ECF will use Speed D...

Page 62: ... be locked restricted for incoming outgoing or both ways 0 Unlock incoming Unlock outgoing 1 Unlock incoming Lock outgoing 2 Lock incoming Lock outgoing Turn CO LED off 3 Lock incoming Lock outgoing Turn CO LED on Related Zones None Zone 606 CO Fre CO 1 of lines Default value 0000000000000000000 Range N A This zone allocates the Frequency of the ringing signal that will be used by each CO line One...

Page 63: ...t 13 and 14 Zone 610 Set 01 01 Zone 611 Set 01 00 Zone 607 Group 01 11 12 Zone 610 Set 02 02 Zone 611 Set 02 00 Zone 607 Group 02 13 14 Example 2 NUMBERS FOR DID ARE 03 9837 2301 DID FOR THE SERVICE DEPT EXT 66 AND 77 03 9837 2302 DID FOR THE SALES DEPT EXT 44 AND 33 03 9837 2304 COMMON INCOMING TRUNK NOT DID 03 9837 2308 DID FOR EXT 22 ALL OTHER NUMBERS ARE NORMAL INCOMING TRUNKS ZONE 610 ZONE 61...

Page 64: ...xcept in set 01 NOTE Zone 504 Item 07 can be used to cancel DID for day night or both Related Zones Z504 Item 07 Z611 NOTE See Zone 242 for Call Forwarding with DID Zone 611 DID S SET indial pair number Default value 00 Range station numbers available This zone allocates the Station number to be paired to an indial CO line A station is allocated to a set in Zone 610 This means that only the statio...

Page 65: ...06 62 Zone 614 EH64 TIME Default value 0000000000000000 Range 0 9 This zone allocates the time in minutes for the EH64 time charge feature Related Zones Z140 Z141 Z142 Z203 Z251 Z307Item 01 Item 07 Z407 Z604 Item 02 Zone 615 to Zone 699 Reserved ...

Page 66: ... 140 ex GST 140 ex GST 90 ex GST This form must be printed from this manual and sent via fax before any service work can be scheduled or completed Rates are also excluding any materials required ...

Page 67: ...Making Communication Easy Aristel AV Series Programming Manual ...