Revised by R. Robinson
Issue AV1.13 8 June 2006
19
DIGIT DIALLED
EXTENSION TO RING
1
Group 01 Item 01
1
Group 01 Item 02
1
Group 01 Item 03
1
Group 01 Item 04
1
Group 01 Item 05
1
Group 01 Item 06
1
Group 01 Item 07
1
Group 01 Item 08
or
DIGIT DIALLED
EXTENSION TO RING
2
Group 02 Item 01
2
Group 02 Item 02
2
Group 02 Item 03
2
Group 02 Item 04
2
Group 02 Item 05
2
Group 02 Item 06
2
Group 02 Item 07
2
Group 02 Item 08
Etc
Related Zones.
Zone 210
ICM Hunting
Default value =
0
Range =
(0 ~ 3)
Allows a calling station to dial 4 on an intercom call to a busy station/ non-answering station and be
transferred to the next free station in the same Station Groupset in
0 = Disable
1 = Enable
Related Zones.
,
Zone 211
Wake Up Call
Default value =
1
Range =
(0 ~ 1)
This Zone allocates the Voice message (0) or BGM (1) for the Wake Up Call function.
Related Zones.
None
Zone 212
SLT Msg Wait Sign
Default value =
1
Range =
(1:R ~ 2:V)
Allows Message Waiting signal to be left for an SLT. It will ring for the time set in
and be silent for
. This continues until the call is answered and then an automatic intercom call is made
to the extension that left the message waiting signal. This Zone must be 0 if SLUC cards are used.
Related Zones.
,
,
Zone 213
Make/Break TYPE
Default value =
0
Range =
(0 ~ 1)
This Zone allocates the Make to Break ratio of the pulse dialer.
0 = 33/66 ratio 1 = 40/60 ratio
Related Zones.