FF3: Extension Programming
Section 400-Programming
Page 3-6
●
DBS 576 (USA) issued 05/20/98
576-13-400
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
0
System
Configuration
FF7
Applications
FF8
Maintenance
Introduction
Appendix A
Appendix B
Notes:
Related Programming:
Notes:
If the hookswitch is held down for less than this timer, but longer than the SLT Hookflash Timer (see
next address), the system will recognize it as a hookflash.
Related Programming:
SLT Hookflash (pg. 3-5) FF3 0 BSSC 03 0 Hold (0 or 1) Hold
SLT Hookflash Timer (pg. 3-7) FF3 0 BSSC 03 3 Hold (0-3) Hold
SLT Dial Type
(all CPCs) - Version 1.0 or higher
Set signaling for dialing on SLT phones.
FF3 0 BSSC 03 1 Hold (0 or 1) Hold
0=Dial pulse
BSSC: Extension Port
B=Cabinet no. 1-6
SS=Slot no. 01-12
C=Circuit no. 1-8
1=DTMF (default)
$
5% %6 $0$7
SLT On-Hook Detection Timer
(all CPCs) - Version 1.0 or higher
Set minimum on-hook time (how long hookswitch must be held down) before
the system disconnects the call. This setting value depends on SLT Hookflash
setting (“Detect” or “Ignore”).
FF3 0 BSSC 03 2 Hold (0-3) Hold
Flash Detect Flash Ignore
BSSC: Extension Port
B=Cabinet no. 1-6
SS=Slot no. 01-12
C=Circuit no. 1-8
0
1
2
3
240 ms
1008 ms
1200 ms
1504 ms
160 ms (default (U.K.)
112 ms (default U.S.)
208 ms
304 ms
$
5% #) .3 %