FF1 1: System Timers
FF1 1 01: Trunk Timer 1
Notes:
Related Programming:
Flash Pattern ...
for analog CO trunks (pg. 2-18) FF2 0 BSSC 02 01 Hold (0 or 1) Hold
for analog E&M tie-trunks (pg. 2-46) FF2 0 BSSC 02 01 Hold (0 or 1) Hold
for T1-CO trunks (pg. 2-97) FF2 2 BSSCC 03 01 Hold (0 or 1) Hold
for T1-E&M tie-trunks (pg. 2-126) FF2 2 BSSCC 03 01 Hold (0 or 1) Hold
1.
1.
Flash Timer 1 for Trunk Line
(all CPCs) - Version 1.0 or higher
Set the length of time a flash signal to a trunk line will last when the
extension user depresses FLASH or PROG. Applies when Flash
Pattern #1 is programmed for the trunk.
FF1 1 01 0001 Hold (1-255) Hold
1 = (1 x 16 ms) = 16 ms
default: 50 = (50 x 16 ms) = 800 ms
2 = (2 x 16 ms) = 32 ms
3 = (3 x 16 ms) = 48 ms
...
124 = (124 x 16 ms) = 1,984 ms or 1.984 seconds
125 thru 255 = same value (2.5 ms)