DSS/72 consoles and EM/24 units require their own port, separate from the phone. To match them to a
phone, assign the same Extension Number to both ports.
Multiple DSS/72 consoles can be assigned to the same keyphone. (EM/24 units are limited to 1 per
phone.)
❒
There is no limit on how many EM/24s can be assigned to a phone, other than the number of ports
available in the system.
❒
DSS/72 assignment is limited by the CPC used:
with a CPC-96:
max. 12 DSS/72 consoles
with a CPC-288:
max. 36 DSS/72 consoles
with a CPC-576:
max. 72 DSS/72 consoles
To view Extension Port/Number assignments in normal operating mode, you must first program an FF-
key with the Extension Port Confirm feature code, *59. See FF4 addresses starting on pg. 4-7 for
programming instructions.
Related Programming:
Phone Type (pg. 3-3) FF3 0 BSSC 00 Hold (1-3) Hold
Notes:
Set this address to “0” (Detect SLT hookflash) to be able to transfer or make conference calls. Set it to
“1” (Ignore SLT hookflash) to avoid unexpected call holding.
Related Programming:
SLT On-Hook Detection Timer (pg. 3-6) FF3 0 BSSC 03 2 Hold (0-3) Hold
SLT Hookflash Timer (pg. 3-7) FF3 0 BSSC 03 3 Hold (0-3) Hold
Extension COS: Brokers Hold on SLTs (pg. 1-42) FF1 0 03 (00-15) 07 Hold (0 or 1) Hold
Extension COS: Hookflash Control on SLTs (pg. 1-43) FF1 0 03 (00-15) 08 Hold (0 or 1) Hold
SLT Hookflash
(all CPCs) - Version 1.0 or higher
Set whether the system will recognize a hookflash on an SLT phone as placing
the call on hold.
FF3 0 BSSC 03 0 Hold (0 or 1) Hold
0=Detect SLT hookflash. (default)
BSSC: Extension Port
B=Cabinet no. 1-6
SS=Slot no. 01-12
C=Circuit no. 1-8
1=Ignore SLT hookflash.
$