– 22 –
Chapter 2 Description of Parts — Rear side
Rear side
1
20
21
22
11
14
12 13
10
15
34
35
38
37
39
40
33
5
6 7 8
9
4
2
3
16
29
30
31
19
17
18
23 24
26
25
27
28
32
36
1
<LIGHT> switch
Used to turn the back panel lamp on/off.
2 <PGM1> dial (<INTERCOM1>)
Used to adjust the level of the audio or mixing ratio set from [MAIN MENU]
→
[INTERCOM SETTING]
→
[LEVEL/PGM1/PGM2 VR SETTING]
→
[INTERCOM1 PGM1 VR].
3 <PGM2> dial (<INTERCOM1>)
Used to adjust the level of the audio or mixing ratio set from [MAIN MENU]
→
[INTERCOM SETTING]
→
[LEVEL/PGM1/PGM2 VR SETTING]
→
[INTERCOM1 PGM2 VR].
4 <TALK> lamp (<INTERCOM1>)
Lights up when the <TALK> switch (<INTERCOM1>) is enabled.
5
<OPT> lamp
Indicates the camera’s optical signal reception status.
Normal:
Lit in green
Error:
Lit in red
@
@
NOTE
t
When an error has occurred, turn off the power of this camera and the CCU, and then clean the optical fiber connector. If the error persists,
immediately turn off the power, and contact your dealer.
6
<RET A> switch
Used to switch the type of the return A image.
7 <REAR>/<INC1 FRONT>/<INC2 FRONT> switch
Used to switch the receiving target of the intercom.
f
<REAR>:
Adjusts the volume level of the intercom using the <LEVEL> dials of <INTERCOM1> and <INTERCOM2> on the rear side.
f
<INC1 FRONT>:
Adjusts the volume level of the intercom 1 using the <INCOM LEVEL> dial (front).
f
<INC2 FRONT>:
Adjusts the volume level of the intercom 2 using the <INCOM LEVEL> dial (front).
8
<RET B> switch
Used to switch the type of the return B image.
9 <CALL> lamp
Lights up in green when the call switch is pressed from the ROP or CCU.
The lamp will flash in the following cases.
f
When the <POWER> switch is set to <EXT>:
If the camera detects that the total current consumption including external DC output exceeds the rating, the lamp will flash in red.
If the camera detects that external DC output exceeds the rating, the lamp will flash in orange.
f
When the <POWER> switch is set to <CCU>:
If the camera detects that the voltage supplied from the CCU is lower than the rating, the lamp will flash in red.
If the camera detects that external DC output exceeds the rating, the lamp will flash in orange.
@
@
NOTE
t
The voltage supplied from the CCU will change depending on the total power consumption which includes the following conditions.
Length of an optical fiber multi cable and the power consumption of the camera which includes the DC output
Attaching AK-HBU500G
10
<TALK> switch (<INTERCOM1>)
This switch is the <ON>/<OFF>/<PTT> selector switch of the intercom microphone connected to the <INTERCOM1> terminal.
Pushes the switch towards <ON>/<PTT> to turn on the microphone.