– 67 –
Chapter 4 Menu Operations — Menu list
Item
Description of settings
[TRUNK1]
Sets the serial interface standard of the <TRUNK> terminal.
[RS422], [RS232C]
f
Factory setting: [RS422]
[TRUNK2]
Sets the serial interface standard of the <TRUNK> terminal.
[RS422], [RS232C]
f
Factory setting: [RS422]
[BACK LIGHT]
Sets the brightness of the backlight.
[1]…[70]
f
Factory setting: [20]
[LAN]
Sets the usage for the <LAN> terminal.
[TRUNK], [PC]
f
Factory setting: [PC]
[B/U LENS]
Sets the lens type of the Build-up Unit.
[PORTABLE], [BOX]
f
Factory setting: [BOX]
[T-BAR CONNECT]
Sets whether to connect the T-BAR unit.
[OFF], [ON]
f
Factory setting: [OFF]
[LENS I/F]
Sets the lens interface.
[ANALOG], [SERIAL]
f
Factory setting: [SERIAL]
[DISPLAY STATUS/BAR
OSD]
[CAM ID CHARACTER]
Sets the camera name.
[GEN-LOCK]
[H PHASE-COARSE]
Roughly adjusts the phase of horizontal synchronization.
[
−
5]…[
+
5]
f
Factory setting: [0]
[H PHASE-FINE]
Finely adjusts the phase of horizontal synchronization.
[
−
100]…[
+
100]
f
Factory setting: [0]
[AUTO SET UP]
This cannot be set in HDR mode.
Item
Description of settings
[FILTER]
Sets the ND/CC filter mode for automatic setup.
[REF], [CURRENT]
f
Factory setting: [REF]
[SETUP MODE]
Sets the mode for automatic setup.
[FULL], [EASY]
f
Factory setting: [FULL]
[REFERENCE FILE]
Sets the reference file for automatic setup.
[FACTORY], [USER1], [USER2], [USER3], [REF1], [REF2], [REF3]
f
Factory setting: [FACTORY]
[MASTER PEDESTAL TARGET]
Sets the master pedestal for automatic setup.
[0.0%]…[7.5%]
f
Factory setting: [3.0%]
[AUTO SET UP EXECUTE]
Selects whether to execute with the configured settings.
[NO], [YES]
[NETWORK SETUP]
[NETWORK SETUP] cannot be selected right after the power is turned on, because boot of the camera is in progress.
This is not an error. Perform operation after a while.
Item
Description of settings
[IP ADDRESS]
Sets the IP address.
f
Factory setting: [192.168.0.30]
[SUBNET MASK]
Sets the subnet mask.
f
Factory setting: [255.255.255.0]
[DEFAULT GATEWAY]
Sets the default gateway.
f
Factory setting: [192.168.0.1]
[HTTP PORT]
Sets the port number of HTTP (port number when accessing with a browser).
[1]…[65535]
f
Factory setting: [80]
[ROP PORT]
Sets the port number when connecting to ROP.
[49152], [49200]…[49299]
f
Factory setting: [49152]
[SET EXCUTE]
Selects whether to execute with the configured settings.
[NO], [YES]
[MAC ADDRESS]
Displays the MAC address. (This cannot be changed.)