Irradiation sensor offset
If an irradiation sensor is to be connected, an offset has to be carried out before
the connection is made.
To carry out the offset, proceed as follows:
Î
Adjust the irradiation sensor type in the Type channel.
Î
Select the Offset channel.
Î
Confirm the reset enquiry with Yes.
Î
Select back to return to the Inputs menu, then connect the irradiation sen-
sor.
In- / Outputs / Inputs
Adjustment
channel
Description
Adjustment range / selection
Factory
setting
S1 … S9
Sensor input selection
-
-
Type
Selecting the sensor type
Switch, KTY, Pt500, Remote
control, Pt1000, OMS,
Impulse (S9 only), None
Pt1000
Offset
Sensor offset
-15.0 … +15.0 K
0.0 K
Inverted
Inverted switching option
(only if Type = Switch)
Yes, No
No
Imp.1
Impulse input (only if Type =
Impulse)
-
-
Vol./Imp.
Impulse rate (only if Type = Impulse) 0.1 … 100.0
1.0
CS10
Irradiation sensor input
-
-
Type
Irradiation sensor type
A … K
E
Offset
Delete offset
Yes, No
No
Gd1, 2
Grundfos Direct Sensor™ digital
1, 2
-
-
Type
Grundfos Direct Sensor™ Type
RPD, VFD, None
None
if Type = VFD:
Measuring range selection
10 - 200 l/min, 5 - 100 l/min,
2 - 40 l/min, 2 - 40 l/min (fast),
1 - 20 l/min, 1 - 12 l/min*
1 - 12 l/min
* For the Inputs Gd1 and Gd2, the following sensor combinations are possible:
- 1 x RPD, 1 x VFD
- 2 x VFD, but with different measuring ranges only
13.3 Outputs
In this menu, the control type and the minimum speed can be adjusted for each
individual relay of the controller and the external modules.
The control type determines the way speed control of a connected pump is ef-
fected. The following modes are available:
Adapter = speed control signal via a S-Bus / PWM interface adapter
0-10 V
= Speed control via a 0-10 V signal
PWM
= Speed control via a PWM signal
Standard = Burst control (factory setting)
With the control types Adapter, 0-10 V and PWM, the relay itself is not in-
volved in speed control. A seperate connection for the corresponding signal will
have to be made (see figure).
If PWM / 0-10 V is selected, the channels Output and Profile appear. In the
Output channel, one of the 2 PWM outputs can be selected. In the Profile chan-
nel, different PWM curves corresponding with the pump in use can be selected.
Note:
If PWM / 0-10 V is selected for an output, the adjustment range for the
corresponding minimum speed will extend to 20 … 100 %.
Note:
For boiler modulation, the 0-10 V outputs A and B can be allocated to a
demand in the Shared relays menu.