Arrangement / Opt. functions / Add new function / Function block
Adjustment
channel
Description
Adjustment range /
selection
Factory setting
Relay
Relay
system dependent
system dependent
Thermostat a Thermostat a
Yes, No
No
Th-a on
Switch-on temperature
thermostat a
-40 … 250 °C
40 °C
Th-a off
Switch-off temperature
thermostat a
-40 … 250 °C
45 °C
Sensor
Sensor thermostat a
system dependent
system dependent
Thermostat b Thermostat b
Yes, No
No
Th-b on
Switch-on temperature
thermostat b
-40 … 250 °C
40 °C
Th-b off
Switch-off temperature
thermostat b
-40 … 250 °C
45 °C
Sensor
Sensor thermostat b
system dependent
system dependent
D
T function
Differential function
Yes, No
No
D
Ton
Switch-on temperature
difference
1.0 … 50.0 K
5.0 K
D
Toff
Switch-off temperature
difference
0.5 … 49.5 K
3.0 K
D
Tset
Set temperature difference
2 … 100 K
10 K
Rise
Rise
1.0 … 20.0
2.0 K
Min speed
Minimum speed
20 … 100 %
30 %
Sen. Source
Heat source sensor
system dependent
system dependent
Sen. Sink
Heat sink sensor
system dependent
system dependent
Timer
Timer
Yes, No
No
Timer FB1
Time frame adjustment
00:00 … 23:45
Day selection Day selection
All days, Monday … Sun-
day, Continue
-
Ref. relay
Reference relay option
Yes, No
No
Mode
Reference relay mode
AND, OR
OR
Relay
Reference relay 1 selection
system dependent
system dependent
Relay
Reference relay 2 selection
system dependent
system dependent
Relay
Reference relay 3 selection
system dependent
system dependent
Funct.
Activation / Deactivation
Activated / Deactivated Activated
Irradiation switch
Arrangement / Opt. functions / Add new function / Irrad. switch
Adjustment
channel
Description
Adjustment range /
selection
Factory setting
Relay
Relay selection
system dependent
system dependent
Irrad.
Switch-on irradiation
50 … 1000 W/m²
200 W / m²
Duration
Switch-on duration
0 … 30 min
2 min
Inverted
Inverted switching option
Yes, No
No
Funct.
Activation / Deactivation
Activated / Deactivated Activated
The Irradiation switch function can be used for operating a relay depending on
the measured irradiation value.
The allocated relay is switched on if the adjusted irradiation value remains exceed-
ed for the adjusted duration. If the irradiation falls below the adjusted value for the
adjusted duration, the relay is switched off.
If the Inverted option is activated, the relay operates vice versa.
Error relay
Arrangement / Opt. functions / Add new function / Error relay
Adjustment
channel
Description
Adjustment range /
selection
Factory setting
Relay
Relay selection
system dependent
system dependent
Funct.
Activation / Deactivation
Activated / Deactivated
Activated
The Error relay function can be used for operating a relay in the case of an error.
Thus, e. g. a signalling device can be connected in order to signal errors.
If the error relay function is activated, the allocated relay will operate when a
sensor fault occurs.