B_PM_UMCbox_en05.doc
5-8
Maintenance
ÖSTLING Markiersysteme GmbH
Slides of the axes
(see page 5-4)
Every 40 operating hours.
1. Switch off the control.
2. Move the slides manually in X- and Y-direction.
Slides must be movable easily by hand.
3. If the slides can be moved only with difficulty: lubricate the guiding rods of
the axes:
1
Rear guiding rod of the X-axis
2
Front guiding rod of the X-axis
3
Left guiding rod of the Y-axis
4
Right guiding rod Y-axis
Marking head without covering cap
Fig. 10191
Check on
smooth running