B_PM_UMCbox_en04.doc
4-14
Operation
ÖSTLING Markiersysteme GmbH
3. Enter the following values:
-
"Value": current value of the counter. Select "User" if the current value
of the counter shall be queried from the user by a message (see also
Fig. 10235, page 4-16).
-
"Begin": minimal value of the counter.
-
"End": maximal value of the counter. Select "User" if the maximal value
of the counter shall be queried from the user by a message (see also
Fig. 10235, page 4-16).
-
"Step": increment to increase the counter.
-
"Repeat": number of markings before the counter is increased one
"Step".
-
"Digits": number of digits marked.
-
"Warning level": number of markings before "End" when the software
displays a message that only x markings can be done before the maxi-
mal value of the counter is reached. When inserting
-1
no message is
displayed.
-
"Reset, Hour", "Reset, Minute": number of operating hours and mi-
nutes after that the counter is reset to "Begin".
4. To assume the object in the object list: select
.
Summary of Contents for PinMark UMC box
Page 14: ...B_PM_UMCbox_en01 doc 1 8 Safety ÖSTLING Markiersysteme GmbH ...
Page 32: ...B_PM_UMCbox_en03 doc 3 12 Description ÖSTLING Markiersysteme GmbH ...
Page 91: ...B_PM_UMCbox_en07 doc ÖSTLING Markiersysteme GmbH Index 7 1 Chapter 7 Index ...
Page 94: ...B_PM_UMCbox_en07 doc 7 4 Index ÖSTLING Markiersysteme GmbH ...
Page 96: ...B_PM_UMCbox_en08 doc 8 2 Drawings parts lists ÖSTLING Markiersysteme GmbH ...
Page 98: ...B_PM_UMCbox_en09 doc 9 2 EC declaration of conformity ÖSTLING Markiersysteme GmbH ...
Page 100: ......
Page 102: ...B_PM_UMCbox_en10 doc 10 2 Service request ÖSTLING Markiersysteme GmbH ...
Page 104: ......