7
GENERAL CONDITIONS
Before starting to control the machine’s movements and functions a se-
ries of essential checks must be carried out and a thorough knowledge
must be gained of the instruMEntatiOn chapter and the functions
that are enabled by the commands, as well as the positioning of the
stOP buttons and the EMErGEnCY devices.
Before doing any operation you must have read, inter-
preted, and correctly implemented all the conditions
indicated previously in the manual and/or annexes.
Commissioning
- Connect the line to the Client’s power supply.
When power is supplied to the machine some unex-
pected movement may occur, so stay at a safe di-
stance.
- switch the power on for the machine using the main switch
IG
and
the machine automatically sets itself up for working.
- Deactivate the EMErGEnCY button activated previously.
- Check that the motor
08
rotates in the correct direction (see the arrow
on the motor itself). If necessary invert the power supply phases and
repeat the operation.
- Push the START button and then immediately the STOP (in some
cases this is the same button with a dual function).
Utilization
- Check that nobody is in the work zone that is not involved in the work.
- switch the power on for the machine again using the main switch
IG
.
- Make sure that the safety devices work properly and that the condi-
tions described are complied with (see the ACCIDENT PREVENTION
chapter).
- read about any rEsiDual risKs and take these into consideration.
- Make sure of the final hose crimping joining diameter
(the final hose
crimping diameter is provided by the pipefitting manufacturer –
follow their instructions)
and insert the most suitable set of dies
06
.
see the dies choice table.
- Make all the settings and proceed with operating as documented below.
ON
7 - Operation