Pag.:
72
Cod.:
001032AG
Cap.:
10
This document is the property of the Manufacturer and/or its
Agent and must not to be tampered with or changed, reproduced or provided to others without written consent.
Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
DD51-E
Direct drive electronic position indicators
The available parameters and their descriptions are listed in the
following table.
Parameter
Description
Available
options
Standard
value
dir
Rotation
direction
--o
clockwise
o--
counterclockwise
--o
OrG
Absolute
reference
value
-9999
;
9999
The parameter value depends on the
unit of measure selected.
0
OFFS
Compensation
values
(Offset)
-9999
;
9999
The system allows you to store up to
10 compensation values:
OFS 0
...
OFS 9
The parameter value depends on the
unit of measure selected.
0
StEP
Reading after
one revolution
0.01
;
100.00
001.00
rES
Resolution
mm:
1
;
0.1
;
0.01
inches:
0.001
;
0.01
;
0.1
;
1
degrees:
0.01
;
0.1
;
1
mm:
0.1
inches:
0.01
degrees:
1
diSP
Display
orientation
0°
:
display right
180°
: display reverse
0°
SPEEd
Reading max
speed [rpm]
300
;
600
;
1000
600
_ _ 0 _ _
Key function
ArCLr
: switching from
ABS
to
REL
the counter is set to zero.
Ar
: switching from
ABS
to
REL
the
counter is not set to zero.
OFF
: the key is not assigned to
any function in the operating mode
ArCLr
_ _ _ _ 0
Key function
ALL
: selectable units of measure:
mm, inch, D
nodEG
: selectable units of measure:
mm, inch
OFF
: the key does not allow the unit
of measure conversion
ALL
0 _ 0 _ _
Key
combination
function
+
L_OrG
: the key combination sets
the absolute value to the sum of
OrG
+
OFFS
parameters
OFF
: lthe key combination is not
assigned to any function in the
operating mode
L_OrG
0 _ _ _ 0
Key
combination
function
+
The key combination activates the
direct programming of the following
parameters:
P_OrG
: parameter
OrG
P_StP
: parameter
StEP
P_OFS
: parameter
OFFS
OFF
: lthe key combination is not
assigned to any function in the
operating mode
P_OrG
PASS
Password
ON
: the system requires the password
22011 to enter the programming mode
OFF
: the system does not require a
password to enter the programming
mode
OFF
Parameter
Description
Available
options
Standard
value
rESEt
Setting of
Parameters
to standard
values
YES
: the parameters are set to the
standard values
NO
: the parameters maintain the
values set by the user
NO
rE
Software
version
The software version is shown on the
display.
9. Problem solving
Message on
the display
Description
Action
-----
Exceeding the reading scale
(-19999;99999)
The value cannot
be shown on the display.
The system continues to
measure displacements; the
value will be shown on the
display again if re-included in
the reading scale.
S_Err
The shaft speed has exceeded the
max system speed.
Press the key to go back to the
value reading and re-set the
absolute reference.
Flashing
battery symbol
Low Battery
Replace the battery
(see paragraph 7.5).