3-15
Section 3
Setting Value Obtaining and Changing Command
ZS Series
CompoWay/F Communication Command Reference
Section 3
Unit No.
and P
a
rameter No.
■
Measurement Setting 1 (Setting per TASK)
Unit No.
(Note 1)
Data No.
Parameter
Setting range/
output range
Remarks
28h 00h
Mode
0: OFF
1: INDIV
2: OPERATION
28h 01h
Input
selection
0: Input A
1: Input B
2: Input C
3: Input D
4: Input E
5: Input F
6: Input G
7: Input H
8: Input I
Parameters when
[Mode]=[INDIV]
28h 02h
Expression
0: THICKNESS (K-(X+Y))
1: STEP (X-Y)
2: K+mX+nY
3: AVE
4: MAX-MIN
Parameters when
[Mode]=[Operation]
28h
03h
Calculation parameter X
28h
04h
Calculation parameter Y
0: Input A
1: Input B
2: Input C
3: Input D
4: Input E
5: Input F
6: Input G
7: Input H
8: Input I
9: TASK 1
10: TASK 2
11: TASK 3
12: TASK 4
Parameters when
[Expression]=
[Thickness], [STEP],
and [K+mX+nY]
28h
05h
Calculation parameter K
-999999999 to 999999999
(nm)
28h
06h
Calculation parameter m
-100 to 100 (X0.1)
28h
07h
Calculation parameter n
-100 to 100 (X0.1)
Parameters when
[Expression]=
[K+mX+nY]