3-19
Section 3
Setting Value Obtaining and Changing Command
ZS Series
CompoWay/F Communication Command Reference
Section 3
Unit No.
and P
a
rameter No.
■
Measurement Setting 2 (common to all TASKs)
Unit No.
Data No.
Parameter
Setting range/
output range
Remarks
78h 00h
Non-measurement
setting
0: Keep
1: Clamp
78h
01h
Output upon clamp
0: MAX
1: 20mA
2: 12mA
3: 4mA
4: MIN
79h
00h
HYS
0 to 999999999 (nm)
79h 01h
Timer
mode
0: OFF
1: OFF DELAY
2: ON DELAY
3: 1 shot
79h
02h
Delay time
1 to 5000 (ms)
7Ah
02h
Monitor focus mode
0: OFF, 1: ON
(Note 2)
7Ah 03h
Monitor focus distance
value 1
-999999999 to 999999999
(nm)
7Ah 04h
Monitor focus distance
value 2
-999999999 to 999999999
(nm)
7Ah 05h
Monitor focus current
value 1
4 to 20 (mA)
7Ah 06h
Monitor focus current
value 2
4 to 20 (mA)
7Ah 07h
Monitor focus voltage
value 1
-10 to 10 (V)
7Ah 08h
Monitor focus voltage
value 2
-10 to 10 (V)
7Dh 04h
Input polarity of external
input 0
7Dh 05h
Input polarity of external
input 1
7Dh 06h
Input polarity of external
input 2
7Dh 07h
Input polarity of external
input 3
0: L active
1: H active
7Eh
00h
External input (IN)
0: None
1: TASK 1
2: TASK 2
3: TASK 3
4: TASK 4
5: TASK ALL
7Eh 01h
External Input
(IN) function mode
0: Standard
1: Bank