2-8
Section 2
About General Information of Communication Commands
ZS Series
CompoWay/F Communication Command Reference
Section 2
Det
ails of Commands
Response
MRC SRC Response
Code
"02" "02"
2 bytes 2 bytes
4 bytes
Elements
Details
Response Code
Indicates controller status for the command.
Response code for normal end
Response Code
Name
Details
"0000"
Normal end
No errors.
Response code when an error occurs
Response Code
Error name
Cause
"1001"
Long command length
Command length is too long.
"1002"
Short command length
Command length is too short.
"1003"
Inconsistent number of
elements/data
Number of elements and data do not match.
"1100"
Parameter error
Data to be written is out of specified range.
"1101"
Area type error
Parameter type is wrong.
"1103"
Start address outside of
range error
Writing start address is out of range.
Writing start address specifies the sensor of the
unconnected Machine No.
"1104"
End address outside of
range error
Specified number of elements is other than "8001."
"2203"
Operating error
Setting is abnormal.
Refer to the User's Manual of the ZS Series for
setting error conditions of thresholds and the
hysteresis width.
"2204"
Operating error
Operating mode of sensor is other than RUN.
"2205"
Operating error
Invalid command.
Writing Parameter Areas