3-25
Section 3
Setting Value Obtaining and Changing Command
ZS Series
CompoWay/F Communication Command Reference
Section 3
Unit No.
and P
a
rameter No.
■
Judgment-related
Unit No.
Data No.
Parameter
Setting range/output range
Remarks
28h 00h Input
source
0: Source A
1: Source B
2: Source C
3: Source D
4: Source E
5: Source F
6: Source G
7: Source H
8: Source I
9: Source J
10: Source K
11: Source L
12: Source M
28h 01h
Threshold lower limit
value
-999999999 to 999999999 (nm)
28h 02h
Threshold
upper limit value
-999999999 to 999999999 (nm)