Setting the Installation Distance
Setting the Installation Distance
Set the distance between the static electricity sensor and the workpiece.
The electric potential value can be corrected according to the change in the distance between the
workpiece and the Sensor Head by performing measurement in combination with a displacement
sensor. The mode to be selected changes according to conditions, such as changes in the
distance between the workpiece and the Sensor Head, or use of the exclusive mounting bracket.
■
Mode selection criteria
■
USER mode
Enter the current distance "d" (fixed) between the workpiece and the Sensor Head.
If "d" changes, enter the sensor distance value again.
Mode
Display
Description
USER mode
USER
When measurement is performed with the distance between the
workpiece and the Sensor Head fixed
(used on static electricity sensor)
AUTO mode
AUTO
When the exclusive jig is not used when the distance between the
workpiece and the Sensor Head changes
(when the static electricity sensor and distance sensor are fixed by the
user's own jig)
FIX mode
FIX
When the exclusive mounting bracket (ZJ-XBU1) is used to install a laser
type Smart Sensor (ZX-LD) or ultrasonic type Smart Sensor (ZX-UD)
when the distance between the workpiece and the Sensor Head changes
Yes
No (fixed)
No
Yes
FIX mode
AUTO mode
USER mode
Does distance between
workpiece and head vary?
Use exclusive mounting
bracket (ZJ-XBU) (sold separately)
for static electricity sensor and
displacement sensor?
Workpiece
d (60 mm)
Static electricity
sensor ZJ-SD