Section 4
Measuring Sheet Workpieces
Mounting on the Device
Mount the Sensor Head on the inspection device.
When mounting the sensor, take care not to exert pressure on the Sensor Head and
wires.
Correcting the Measurement Reference Voltage
Correct the electric potential that becomes the reference for measuring static electricity.
Correcting the Measurement Reference Voltage p.36
Setting the Measurement Mode
Select either the standard mode or high-precision mode.
Selecting the Measurement Mode p.40
Setting the Distance Measurement Mode
Select one of the USER, AUTO and FIX modes.
If the distance between the workpiece and the sensor is fixed, select the USER mode. If the
distance varies, select the AUTO mode. If the distance varies and the exclusive mounting bracket
(ZJ-XBU1) is used for securing the sensor, select the FIX mode.
Setting the Installation Distance p.41