Specifications and Dimensions
Calculating Unit
ZX-CAL2
Item
ZX-CAL2
Applicable Amplifier Units
ZX series, ZJ-S series
Current consumption
12 mA or less (supplied from the Amplifier Unit)
Ambient temperature
Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Connection method
Connector
Dialectic strength
1,000 VAC, 50/60 Hz for 1 min
Insulation resistance
100 M
Ω
(at 500 VDC)
Vibration resistance (destructive)
10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions
Shock resistance (destructive)
300 m/s
2
3 times each in 6 directions (up/down, left/right, forward/backward)
Materials
Display: Acrylic, Case: ABS resin
Weight (packed state)
Approx. 50 g
8
12
15.1
30
2
6
57
54.9
5
36.7
3
.4
24.9
(unit: mm)