Setting the Number of Samples to Average
Setting the Number of Samples to Average
The average of the measured values obtained based on the preset number of samples can be
output. This setting can be used when you want to ignore rapid changes in measured values.
Note, however, that if this setting is made, the response time for judgment and linear outputs
drops.
Moving to the FUN mode and AVE
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT keys to display
[AVE] on the main display.
Selecting the number of samples to average
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Use the UP and DOWN keys to select the
desired number of samples to average.
5.
Press the ENT key to confirm the setting.
This registers the setting.
Selection for No. of
samples to average
Response time
1
2 ms
2
3 ms
4
5 ms
8
9 ms
16
17 ms
32
33 ms
64
65 ms
128
129 ms
256
257 ms
512
513 ms
1024
1025 ms
In the case of the static electricity sensor head, the
number of samples to average has been set to 64
before shipment from the factory.
In general, when the number of samples to average is
multiplied by "n", the resolution increases by
.
n