17
ZJ-SD
User’s Manual
S
ect
io
n
2
P
R
E
P
ARA
T
IO
N
FO
R
ME
ASUR
EM
ENT
Section 2
Mounting on the Mounting Bracket
Mounting on the Mounting Bracket
The following describes how to mount the laser type Smart Sensor (ZX-LD) and static
electricity sensor (ZJ-S), or ultrasonic type Smart Sensor (ZX-UD) and static electricity sensor
(ZJ-S) onto the exclusive mounting bracket (ZJ-XBU1).
Setting the Installation Distance
■
Installation
■
Example of mounting the ZX-LD___
1.
Fix the ZX-LD___ onto the mounting bracket (ZJ-XBU1) using M3 screws.
The screws must be tightened with a torque of 0.3 Nm or less.
Take care not to touch the emitting/receiving section of the Sensor Head. Adhesion of finger marks may
prevent correct measurements. If you have touched them, wipe them with a clean, soft cloth.
2.
Fix the ZJ-S___ using the screws.
Do not allow anything to touch the metal case of the Sensor Head. Failure to do so might prevent accurate
measurement by the sensor.
Emitting/receiving
section
Sensing
section
operation2.book Page 17 Wednesday, November 29, 2006 2:56 PM