
78
S
e
ct
ion 5
DETAILE
D
S
E
TTINGS
ZJ-SD
User’s Manual
Section 5
Linear Output
6.
Use the LEFT and RIGHT keys to display
[RESET] on the main display.
Selecting output status at non-measurement
7.
Press the UP or DOWN key.
The sub-display flashes.
8.
Use the UP and DOWN keys to select either
KEEP or CLAMP.
9.
Press the ENT key to confirm the setting.
This registers the setting.
Next, set the clamp value if [CLAMP] is selected.
Setting the clamp value (only when CLAMP is selected)
10.
Use the LEFT and RIGHT keys to display
[CLAMP] on the main display.
[CLAMP] is not displayed if [KEEP] has been selected.
11.
Press the UP or DOWN key.
The sub-display flashes.
12.
Select the clamp value.
13.
Press the ENT key to confirm the setting.
This registers the setting.
operation2.book Page 78 Wednesday, November 29, 2006 2:56 PM