Setting Judgment Output Timing (Timer)
Setting Judgment Output Timing (Timer)
The timing of judgment outputs can be adjusted to match the operation of external devices.
Selection
Details
OFF
(default)
The judgment is output as soon as the
judgment result has been confirmed.
OFF-D
(OFF-delay timer)
After the judgment result has been
confirmed, changing of the PASS
output state to OFF is delayed by the
time set to the timer.
Also, changing of the HIGH and LOW
output states to ON is delayed by the
time set to the timer.
ON-D
(ON-delay timer)
After the judgment result has been
confirmed, changing of the PASS
output state to ON is delayed by the
time set to the timer.
Also, changing of the HIGH and LOW
output states to OFF is delayed by the
time set to the timer.
ON
OFF
ON
OFF
ON
OFF
Measured value
HIGH threshold
LOW threshold
HIGH output
PASS output
LOW output
ON
OFF
ON
OFF
ON
OFF
Timer time
Timer time
Measured value
HIGH threshold
LOW threshold
HIGH output
PASS output
LOW output
ON
OFF
ON
OFF
ON
OFF
Timer time
Timer time
Measured value
HIGH threshold
LOW threshold
HIGH output
PASS output
LOW output