Z500
Setup Manual
SECTION 3
3-2
RS-232C
Con
n
ection
s
53
SECTION 3
Connecting External Devices
3-2-2 Wiring
The maximum cable length is 15 m.
Standard Wiring
Wiring for RS/CS Control
3-2-3 Connection
Align the connector with the socket and press the connector straight into place.
Tighten the two screws on the edges of the connector.
NOTICE
• Always turn OFF the power supply before connecting or disconnecting cables. The
peripheral device may be damaged if connected or disconnected with the power supply
turned ON.
• Always tighten the connector screws.
Pin No.
Z500
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
2
3
4
5
9
Pin No.
External device
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
*
*
*
*
*
Use a shielded cable.
* Pin numbers on the external device will depend on the device being connected.
Refer to the manual for the personal computer or PLC being connected.
Pin No.
Z500
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
2
3
4
5
9
Pin No.
External device
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
*
*
*
*
*
Use a shielded cable.
Z500