Z500
Setup Manual
SECTION 1
Wiring and Connection
1-2 Component Names and Functions
1-2-1 Sensor
1. Provides laser beam warning indicators.
• For 15 to 25 seconds after the power supply is turned ON, both indicators
will be OFF indicating that the laser beam is OFF.
• When the laser beam turns ON, both indicators will light.
• When the laser beam turns OFF, both indicators will turn OFF.
2. Emits laser beam.
3. Receives laser beam.
4. Light used when displaying surrounding images.
5. Captures surrounding images.
6. Used for switching between display of surrounding images and measurement.
To display surrounding images, move the beam cover lever to the left. To
perform measurement, move the lever to the right.
CHECK
Tighten the lever screws with a flat-bladed screwdriver to a torque in the range 0.15 to 0.3
N
·
m (1.5 to 3 kgf·cm).
CHECK
When Using the Z500-SW2T
• When performing measurement with the beam cover removed, attach the monitor cap
provided with the Sensor over the Light and Monitor in the way shown on the next page.
• When displaying surrounding images, be sure to attach the beam cover. Surrounding
images cannot be displayed correctly without the beam cover attached.
2. Emitter
3. Receiver
Z500-SW2T
1. LASER indicators
4. Light
6. Beam cover
5. Monitor
2. Emitter
Z500-SW6/Z500-SW17
3. Receiver
1. LASER indicators
Display of
surrounding images
Move the beam cover
lever to the left.
Measurement
Move the beam cover
lever to the right.