Ambient temperature
• Maintain a minimum clearance of 50 mm above and below the Z500 to
improve air circulation.
• Do not install the Z500 immediately above significant heat sources, such as
heaters, transformers, or large-capacity resistors.
• Do not let the ambient temperature exceed 50 ºC.
• Provide a forced-air fan cooling or air conditioning if the ambient temperature
is near 50 ºC so that the ambient temperature never exceeds 50 ºC.
Ambient illumination
• Do not let the ambient illumination exceed 3000lx.
• When using the Z500 near lighting equipment that turns ON and OFF
continuously, reduce the influence of the light by, for example, using a light
baffle.
Noise resistance
• Do not install the Z500 in a cabinet containing high-voltage equipment.
• Do not install the Z500 within 200 mm of power cables.
Sensor Maintenance
Install the Sensor in a clean environment and keep the filter on the front panel of
the Sensor free from oil and dust. If affected by oil or dust, clean the filter as
follows:
• Use a blower brush (used to clean camera lenses) to blow large dust particles
from the surface. Do not blow the dust away with your mouth.
• Use a soft cloth (for lenses) with a small amount of alcohol to remove the
remaining dust. Do not use a scrubbing action when cleaning as scratches on
the filter could result in the Sensor malfunctioning.
Sensor replacement
To replace the sensor being connected to the controller, turn OFF the download
function.
Control panel
Z500
Louver
Z500
Z500
200 mm min.
200 mm min.
Power cable
Z500