![background image](http://html.mh-extra.com/html/omron/z500-sw17/z500-sw17_setup-manual_743396034.webp)
32
SE
CTION 2
2-2 Mo
unting
th
e Senso
r
Z500
Setup Manual
SECTION 2
Installation
2-2 Mounting the Sensor
Up to 2 Sensors can be connected per Controller.
NOTICE
Only controllers designed specifically for the Z500 can be used.
Using another type of controller may result in damage to the sensor or controller.
2-2-1 Sensor Types
CHECK
Distance to measurement center (A), Height (B), Width (D), and Spot diameter (C)
Type
Distance to
measurement
center (A)
Measurement range
Spot diameter
(C)
Height
(B)
Width
(D)
Super High-precision
Model
Z500-SW2T
20 mm
±0.8 mm
B= +0.8 mm : 4.0 mm (The width of the
measurement region is 2.2 mm.)
B= 0 mm : 4.0 mm (The width of the
measurement region is 2.3 mm.)
B= -0.8 mm : 4.0 mm (The width of the
measurement region is 2.4 mm.)
B= +0.8 mm : 40
µ
m
B= 0 mm : 20
µ
m
B= -0.8 mm : 40
µ
m
Z500-SW6
50 mm
±5 mm
B = + 5 mm : 23.0 mm (The width of
the measurement region is 6.0 mm)
B =
0 mm : 24.0 mm (The width of
the measurement region is 6.3 mm)
B = - 5 mm : 26.0 mm (The width of
the measurement region is 6.8 mm)
B= + 5 mm : 140
µ
m
B= 0 mm : 30
µ
m
B= - 5 mm : 140
µ
m
Long-range Model
Z500-SW17
100 mm
±20 mm
B= +20 mm : 40 mm (The width of the
measurement region is 14.5 mm.)
B= 0 mm : 45 mm (The width of the
measurement region is 17.3 mm.)
B= -20 mm : 50 mm (The width of the
measurement region is 20.1 mm.)
B= +20 mm : 280
µ
m
B= 0 mm : 60
µ
m
B= -20 mm : 280
µ
m
Line beam
Line beam
D
Z500-SW2T
D
Z500-SW17
C
A
B
+0.8mm
0mm
-0.8mm
+20mm
0mm
-20mm
Front View
Z500-SW6
Line beam
D
+5mm
0mm
-5mm