3-3 Linear Sensor Controller Connections
3-3-1 Crimp Terminals and Cables
The terminal block uses M3 terminal screws.
Use appropriate crimp terminals for M3 screws as shown below.
Tighten the screws to a torque of between 0.5 and 0.6 N·m.
Recommended Crimp Terminals
3-3-2 Terminal Names
NOTICE
Re-cover the terminal blocks with the Terminal Block Protection Covers. Uncovered
terminal blocks can result in electric shock.
Type
Manufacturer
Model
Recommended
wire size
Forked
J.S.T. Mfg Co., Ltd.
V1.25-B3A
1.31 to 1.65 mm
2
Round
J.S.T. Mfg Co., Ltd.
V1.25-MS3
6.0 mm max.
6.0 mm max.
4to20mA -5to5V
0
Analog output terminal for current output in the range 4 to 20 mA.
Analog output terminal for voltage output in the range -5 to 5 V.
Analog output ground connected to input devices.