Service Manual

2023491-201rB 

Summary of Contents for AED Pro

Page 1: ...Service Manual 2023491 201rB...

Page 2: ...nk STAR IntelliSense RescueReady RescueLink RHYTHMx and Survivalink are trademarks and registered trademarks of Cardiac Science Corp Microsoft and Windows are registered trademarks of Microsoft Corpor...

Page 3: ...k of the Responder AED Pro Responder AED Pro is manufactured for GE Medical Systems Information Technologies Inc 8200 West Tower Avenue Milwaukee WI 53223 USA Tel 800 558 7044 USA only Fax 800 421 684...

Page 4: ...ATOR TRAINING REQUIREMENTS 13 INTELLISENSE Battery 14 RECHARGEABLE BATTERY 16 DEFIBRILLATION ELECTRODES PADS 17 AED INDICATORS 18 SETTING THE AED INTERNAL CLOCK 20 SECTION 3 MAINTENANCE TROUBLESHOOTIN...

Page 5: ...Page iv of 33 2007 General Electric Company 2023491 201 Rev B THIS PAGE INTENTIONALLY LEFT BLANK FOR YOUR NOTES...

Page 6: ...nder AED PRO SAFETY TERMS AND CONDITIONS The triangle attention symbol shown below left identifies the potential hazard categories The definition of each category is as follows DANGER This alert ident...

Page 7: ...rsonnel CAUTION Temperature Humidity Pressure Extremes Exposing the AED to extreme environmental conditions outside of its operating parameters may compromise the ability of the AED to function proper...

Page 8: ...dical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Anybody who connects additional equipment to the signal input part or signal output part configures a...

Page 9: ...29 Classified by ETL Semko with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 CAN CSA C22 2 No 601 1 M90 EN60601 1 and EN60601 2 4 Conforms to UL Standard UL...

Page 10: ...te province and country regulations Do not incinerate or expose to open flame Explosion Hazard Do not use in the presence of a flammable gas including Concentrated oxygen Upper and lower temperature l...

Page 11: ...rain Keep dry This way up Stacking limit by number General symbol for recovery recyclable Humidity Limitations Atmospheric Pressure Limitations In November 2005 the American Heart Association AHA and...

Page 12: ...and deliver a shock by pushing the SHOCK button The AED can also provide non diagnostic ECG monitoring INDICATIONS FOR USE INTENDED USE The AED with STAR Biphasic Waveform is intended to be used by p...

Page 13: ...S INTERRUPTED STOP PATIENT MOTION to warn the operator The AED will then proceed to reanalyze the rhythm and continue with the rescue NON COMMITTED SHOCK After the AED advises a shock it continues to...

Page 14: ...Liaison Committee on Resuscitation ILCOR Upon detecting a shockable cardiac rhythm the AED advises the operator to press the SHOCK button to deliver a shock and then advises the operator to start CPR...

Page 15: ...al Date of Installation in an AED Number of Charges completed Time in Operation hours minutes Days of Standby Operation Battery Capacity Remaining BATTERY OPERATING LIFE The battery operating life dep...

Page 16: ...G Battery Model 2023681 001 is Not Rechargeable Do not attempt to recharge the battery Any attempt to recharge the battery may result in an explosion or fire hazard CAUTION Lithium Sulfur Dioxide Batt...

Page 17: ...ed early by removing the charger cable from the battery If the battery is charged for a minimum of 3 hours the stated capacities will be met Model Estimated Shelf Life Warranty Typical Shocks 2023681...

Page 18: ...l is visible through the clear window on the lid The expiration date of the pads will then be readable without opening the lid of the AED 3 Match the color of the connectors red to red slightly lift t...

Page 19: ...thly self test determines service is required an audible beep is sounded every 30 seconds until the lid is opened or the battery power is depleted Opening and closing the lid may deactivate the beep I...

Page 20: ...s System initialization occurs when the lid is first opened The text display shows the operator the identifiers for the internal code voice prompts and text prompts versions H CPR Counter During CPR a...

Page 21: ...led and the user enters manual mode the AED will remain in the manual mode Further AED rhythm analysis and CPR prompting are disabled when Remain in Manual Mode is enabled SETTING THE AED INTERNAL CLO...

Page 22: ...ically Turns itself ON and the STATUS INDICATOR changes to RED Performs the self test If successful the STATUS INDICATOR reverts to GREEN Turns itself OFF if the lid is closed There are three types of...

Page 23: ...ery is low Replace with a new battery The battery power is completely depleted Replace with a new battery If STATUS INDICATOR remains RED refer to the Responder AED Pro for maintenance Call Customer S...

Page 24: ...12 Close the lid Check the Integrity of the Service Indicator LED and Circuitry 1 Immediately after opening the AED lid press and hold the SHOCK button and confirm that the SERVICE LED is lit 2 Relea...

Page 25: ...Note Detailed instructions for using the ServiceLink software can be found in the ServiceLink manual provided on the ServiceLink software CD 1 Use ServiceLink to ensure the AED is set to a known proto...

Page 26: ...atic shock advisory AUDIBLE ALERTS Voice Prompt Maintenance Alert VISIBLE INDICATORS STATUS INDICATOR Display Panel BATTERY Indicator NUMBER OF SHOCKS DELIVERED Indicator ELAPSED RESCUE TIME Indicator...

Page 27: ...lead wire 1 3m LITHIUM BATTERY SPECIFICATIONS Output voltage 12VDC max Batteries are non rechargeable Lithium contents 9 2g max Check local regulations for disposal information Model Estimated Shelf...

Page 28: ...arged AED to maximum energy The maximum time from Power On to Ready to Shock is 28 seconds for a new rescue The maximum time from Analyze to Ready to Shock is 22 seconds for a new rescue AED SELF TEST...

Page 29: ...d C22 2 No 601 1 M90 Electrical Construction Safety and Performance IEC 60601 1 1998 Amendments 1 1991 2 1995 IEC 60601 2 4 2002 IEC 60601 1 4 2000 ANSI AAMI DF 39 1993 Electromagnetic Compatibility E...

Page 30: ...liance Free Fall Drop IEC 60068 2 32 1975 AM 2 1990 1 meter Bump IEC 60068 2 29 1987 40g and 6000 bumps Vibration Random IEC 60068 2 64 1993 10Hz 2KHz 0 005 0 0012 g2 Hz Vibration Sine IEC 60068 2 6 1...

Page 31: ...t is compliant with ANSI AAMI DF2 and DF39 The following is a graph of the waveform voltage as a function of time when the AED is connected to a 50 Ohm resistive load See figure A1 and Tables A1throug...

Page 32: ...e typical Phase 1 Phase 2 Patient s Impedance Ohms Voltage Volts Duration ms Voltage Volts Duration ms Energy Joules 25 1885 3 3 990 3 2 265 360 50 1920 4 5 1240 3 2 235 320 75 1930 5 8 1325 3 2 215 2...

Page 33: ...placing the into service The AED s factory default rescue protocol is 200 300 300 Joule J escalating Variable Energy VE The first shock is delivered within the range of 140J 250J 200J nominal Subseque...

Page 34: ...arrest CARDIAC RHYTHMS USED TO TEST THE RHYTHM RECOGNITION DETECTION SYSTEM FOR CARDIAC SCIENCE AED Rhythm Class Specifications Shockable Rhythm VF Meets AAMI DF 39 requirement and AHA recommendation...

Page 35: ......